About Co-Axial Three Finger Clamp
KFW Co-Axial Three Finger Clamp
Made of aluminium al-alloy jaws with rubber sleeves, spring controlled adjustable by co-axial brass nut, hold upto 75mm dia articles, rod length 12" x 3/8 chrome plated.
KFW - C37 A Co-Axial Three Finger Clamp
Same as above,Jaws made of brass moulding & chrome plated
Reliable and Flexible Laboratory GripThe Co-Axial Three Finger Clamp delivers exceptional holding capacity for a range of laboratory apparatus including glassware and burettes. Its uniquely designed co-axial tightening mechanism enables precise control, ensuring a secure grip every time. With 360-degree rotational freedom, it accommodates various experimental setups efficiently.
Durable Construction and Safety FeaturesConstructed with nickel-plated brass or heavy-duty die-cast metal and finished for corrosion resistance, this clamp ensures long-lasting durability. The non-slip, rubber-coated grips and heat-resistant properties provide confidence and safety during standard laboratory heating applications. Its compatibility with standard rods and stands further enhances its utility.
FAQs of Co-Axial Three Finger Clamp:
Q: How do I operate the co-axial tightening mechanism on this clamp?
A: The co-axial spindle tightening mechanism is designed for effortless single-handed operation. Simply use the thumb screw to adjust jaw pressure until it securely holds your equipment. The smooth threading allows for fine control while maintaining a firm grip.
Q: What equipment can be secured with this three finger clamp?
A: This clamp is suitable for securing laboratory glassware, burettes, and columns with diameters up to 16 mm. The jaws open 0-90 mm, which accommodates most standard laboratory apparatus used for holding, suspending, or heating.
Q: When should I use this clamp in laboratory settings?
A: Use this clamp whenever you need a stable, hands-free support for glassware or similar equipment during experiments, especially when heating, titrating, or conducting setups that require apparatus to remain in a fixed position.
Q: Where can the clamp be mounted?
A: The clamp is compatible with standard laboratory rods and stands. Attach it to rods up to 16 mm in diameter and position it as required for your experiment, making it suitable for use in chemistry, biology, or physics labs.
Q: What are the benefits of 360-degree rotation and rubber-coated grips?
A: The 360-degree rotation allows you to orient your equipment at any angle without removing the clamp, enhancing workflow flexibility. The rubber or PVC-coated grips prevent slippage and minimize the risk of damage to sensitive laboratory glassware.
Q: Is this clamp resistant to chemicals and heat?
A: Yes, the clamp is constructed from nickel-plated brass or heavy-duty die-cast metal, providing resistance to most laboratory chemicals and corrosion. It is also suitable for use with standard laboratory heating applications under ambient conditions.