Back to top
FTIR Spectrometer
FTIR Spectrometer

FTIR Spectrometer

FTIR Spectrometer Specification

  • Temperature Range
  • Ambient to 80C for sample compartment
  • Capacity
  • Sample compartment size: Standard, suitable for typical research and industrial applications
  • Feature
  • Rapid scan, high sensitivity, software integration
  • Frequency
  • Spectral range: 7800 - 350 cm1
  • Power Source
  • AC supply, 100-240V, 50/60Hz
  • Core Components
  • Interferometer, IR source, detector, beam splitter
  • Automation Grade
  • Fully automatic
  • Measurement Range
  • 7800 to 350 cm1
  • Model No
  • FTIR-2404
  • Accuracy
  • Wavelength accuracy: 0.01 cm1
  • Voltage
  • 100-240 V, 50/60 Hz
  • Equipment Materials
  • Corrosion-resistant metal housing, optical-grade crystals
  • Type
  • Fourier Transform Infrared (FTIR) Spectrometer
  • Usage
  • Qualitative and quantitative infrared analysis
  • Display Type
  • High-resolution LCD touch screen display
  • Dimension (L*W*H)
  • 500 x 380 x 210 mm
  • Weight
  • Approx. 20 kg
  • Aperture Size
  • Adjustable
  • Resolution
  • Up to 0.5 cm1
  • Sample Types
  • Solid, liquid, gas samples
  • Humidity Control
  • Optional purge system for moisture-sensitive analysis
  • Scan Speed
  • Up to 20 scans/second
  • Optics
  • Gold-coated mirrors for optimal reflectance
  • Software
  • Included proprietary analysis software, compatible with windows OS
  • Detector Type
  • DLATGS
  • Portability
  • Bench-top
  • Data Output
  • USB & Ethernet connectivity
  • Interferometer
  • Michelson-type, sealed for stability
  • Laser Type
  • He-Ne laser for wavelength calibration
 
 

About FTIR Spectrometer

We provide FTIR Spectrometer which is used for fourier transform infrared spectroscopy (FTIR).

 

Features:-


  • New type cube-corner Michelson interferometer features smaller size and more compact structure, providing higher stability and less sensitive to vibrations and thermal variations than conventional Michelson interferometer.
  • Fully sealed damp and dust proof interferometer, adopting high performance, long lifetime sealing material and desiccator, ensures higher adaptability to the environment and increases accuracy and reliability in operation. Viewable window for silica gel enables easy observation and replacement.
  • Isolated IR source and large space heat dissipation chamber design provides higher thermal stability. Stable interference is obtained without the need of dynamic adjustment.
  • High intensity IR source adopts a reflex sphere to obtain even and stable IR radiation.
  • Cooling fan stretch suspending design ensures good mechanical stability.
  • Super wide sample compartment provides more flexibility to accommodate various accessories.
  • The application of programmable gain amplifier, high accuracy A/D converter and embedded computer improves the accuracy and reliability of the whole system.
  • The spectrometer connects to PC via a USB port for automatic control and data communication, fully realizing plug-and-play operation.
  • Compatible PC control with user friendly, rich function software enables easy, convenient and flexible operation. Spectrum collection, spectrum conversion, spectrum processing, spectrum analyzing, and spectrum output function etc. can be performed.
  • Various special IR libraries are available for routine search. Users can also add and maintain the libraries or set up new libraries by themselves.
  • Accessories such as Defused/Specular Reflection, ATR, Liquid cell, Gas cell, and IR microscope etc can be mounted in the sample compartment.

 

Specifications:-


Spectral Range

7800 to 350 cm-1

Resolution

Better than 0.85cm-1

Wave Number

±0.01cm-1

Scanning Speed

5-step adjustable for different applications

Signal to noise ratio

better than 15,000:1 
(RMS value, at 2100cm-1, resolution: 4cm-1, detector: DTGS, 1 minute data collection)

Beam splitter

Ge coated KBr

Infrared Source

Air-cooled, high efficiency Reflex

Detector

DTGS

Data system

Compatible computer

Software

FT-IR software contains all routines needed for basic spectrometer operations, including library search, quantitation and spectrum export

IR Library

11 IR libraries include




Advanced Optical Performance and Stability

Equipped with gold-coated mirrors and a Michelson-type sealed interferometer, the FTIR-2404 delivers outstanding signal stability and optimal reflectance across its wide spectral range. The He-Ne laser ensures precise wavelength calibration, while robust optical-grade components make it suitable for demanding laboratory and industrial environments.


Versatile Sample Handling and Efficiency

Supporting solids, liquids, and gases in a standard-sized sample compartment, the FTIR-2404 accommodates diverse analytical needs. Rapid scan capability, an ambient to 80C temperature range, and an optional humidity control system enable accurate results, even for moisture-sensitive materials. Fully automated operation streamlines workflows for consistent performance.


Intuitive Software and Connectivity

The included proprietary software, compatible with Windows OS, simplifies data acquisition, analysis, and reporting. With high-resolution LCD touch display, USB, and Ethernet connections, users benefit from straightforward control, flexible access, and effortless exporting of data in various environments.

FAQ's of FTIR Spectrometer:


Q: How does the DLATGS detector benefit my infrared analyses using the FTIR-2404?

A: The DLATGS (deuterated L-alanine-doped triglycine sulfate) detector in the FTIR-2404 offers high sensitivity and a rapid response, allowing for accurate detection of spectral features, even with weakly absorbing samples. This enhances both qualitative and quantitative results across various sample types.

Q: What types of samples can I analyze with this FTIR spectrometer?

A: The FTIR-2404 is designed to analyze solid, liquid, and gas samples, making it highly versatile for research or industrial settings. Its adjustable aperture and spacious compartment accommodate conventional sample holders for a wide range of applications.

Q: When should I use the optional humidity purge system?

A: Utilize the optional humidity purge system when analyzing moisture-sensitive samples or in environments where atmospheric water vapor can interfere with infrared measurements. This feature helps maintain measurement precision and consistency.

Q: Where can I export and manage data generated from the FTIR-2404?

A: Data can be exported via USB or Ethernet connectivity to computers or network storage. The included proprietary software allows efficient data management, analysis, and report generation on Windows operating systems.

Q: How does the wavelength calibration process work in the FTIR-2404?

A: The FTIR-2404 uses a built-in Helium-Neon (He-Ne) laser to provide precise wavelength calibration. This ensures high accuracy (up to 0.01 cm1), guaranteeing reliable spectral data repeatability across all measurements.

Q: What safety and material features enhance the instrument's durability?

A: The instrument features a corrosion-resistant metal housing and optical-grade crystals, ensuring long-term durability in various environments. The sealed interferometer design further protects sensitive internal components from contaminants and moisture.

Q: What are the main benefits of choosing this benchtop model for analysis?

A: Opting for the FTIR-2404 means benefiting from high scan speeds, superior sensitivity, full automation, flexible sample handling, and robust construction. All these features combine to simplify workflows, improve productivity, and maintain reliable analytical performance.

Tell us about your requirement
product

Price:  

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Scientific Instruments Category

Liquid Chromatography System

Liquid Chromatography System

Usage : Laboratory analysis of liquid samples, purification, and separation

Type : Automated Liquid Chromatography System

Model No : LCS500

Weight : Approx 25 kg

Temperature Range : Room Temperature to 60°C

Equipment Materials : Corrosionresistant stainless steel and chemically resistant polymers

Digital Flame Photometers

Digital Flame Photometers

Usage : Laboratory chemical analysis of Na, K, Li, Ca

Type : Laboratory Flame Photometer

Model No : DFP1

Weight : Approx. 6 kg

Temperature Range : Ambient to 900°C

Equipment Materials : MS Powder Coated & SS Parts

Physics Lab Experiment Kits

Physics Lab Experiment Kits

Usage : For student physics experiments (optics, mechanics, electricity, magnetism, heat)

Type : Educational Physics Lab Kit

Model No : PHEX2024

Weight : Approx. 4.5 kg (complete kit)

Temperature Range : 10°C to 110°C

Equipment Materials : Highgrade plastic, aluminum, glass, copper, and iron components

Atomic Absporption Spectrophotometer

Atomic Absporption Spectrophotometer

Usage : Elemental analysis in laboratories

Type : Atomic Absorption Spectrophotometer

Model No : AA6300

Weight : Approx. 65 kg

Temperature Range : Ambient to 3000°C (Atomizer)

Equipment Materials : Corrosionresistant alloy and stainless steel