Microprocessor Soil Analysis Kits offered can deliver working in PH range of 0-14 pH, pH resolution of 0.01pH, pH accuracy of + 0.01 pH (relative) as well as automatic & manual calibration support.
PH:
Range : 0-14 pH
Resolution : 0.01pH
Accuracy : + 0.01 pH ( relative)
Temp. Comp. : Automatic with Pt100 Sensor
Buffer Recognition : 4.00 , 7.00 , 9.20 ( Automatic)
Calibration : Automatic & Manual
Dissolved Oxygen:
Range : 0 to 20 ppm
Resolution : 0. 1 ppm
Calibration : Automatic
Accuracy : + 0.2 ppm + 1digit
Temp. Comp. : Automatic with Pt100 Sensor
Pressure comp. : 0-999 mm of Hg ( Manual)
Salinity Correction : 0-20 mg/l
mv/ORP:
Range : - 2000 to +2000 mV
Resolution : 1 mV
Calibration : Manual
Accuracy : + 0.1% + 1digit
Temperature:
Range : -100 to +200 degree C
Resolution : 0.1 degree C
Accuracy : + 0.2% + 1digit
Input : Pt100
Calibration : Manual
Conductivity:
Range : 0-200.0 mS/cm
Range Selection : Automatic
Resolution : 0.01 uS/cm
Accuracy : + 0.5%
Temp. Comp. : Automatic with Pt100 Sensor
Ref. Temp. : 25 degree C
Temp. Co-efficient : 0-4% adjustable
Cell constant : 0.05 to 2.0 adjustable
TDS:
Range : 0-200 ppt
Range Selection : Automatic
Resolution : 0.1 ppm
Accuracy : + 0.5%
TDS factor : 0.5 by default( adjustable)
Salinity:
Range : 0-50 ppt
Resolution : 0.1 ppt
Temp. comp. : Automatic
Accuracy : + 0.5%
Salinity factor : 0.75 by default( adjustable)
General Display : 16 characters X 2 linesalpha Numeric BL LCD
Display format : Temp. and parameter Simultaneously
Controls : By soft keys Menu Driven
Storage : up to 1000 samples
Power supply : 230 V +10 % 50 Hz OR 12 V b
Option:
RS232 output available for interfacing to computer/printer
Accessories:

Price:
Core Components : Heating block, digital controller, observation magnifier
Display Type : Digital backlit LCD display
Accuracy : ±1°C
Power Source : Electric (AC mains)
Feature : Bright LED illumination, keypad operation, reset function
Temperature Range : Ambient to 350°C
Core Components : Microprocessor, PH Electrode, Temperature Sensor
Display Type : Digital LCD Display
Accuracy : ±0.01 pH, ±0.1°C
Power Source : AC Adapter
Feature : Automatic Temperature Compensation, Data Hold, Calibration
Temperature Range : 0°C to 100°C
Core Components : Microprocessor, LCD, Optical Sensor
Display Type : Digital LCD Display
Accuracy : ±2%
Power Source : AC Adapter / Battery Powered
Feature : Fast test result, Userfriendly interface, Portable, Lightweight, Reliable
Temperature Range : 10°C to 40°C
Core Components : HEPA Filter, Blower Motor, UV Light
Display Type : Digital display for airflow and pressure
Accuracy : HEPA filter particle removal ≥0.3 microns
Power Source : Electric
Feature : 99.99% efficiency, low noise, high air cleanliness
Temperature Range : Ambient to 50°C