Plasma Thawing Bath Specification

  • Voltage
  • 220V AC
  • Power Source
  • Electric
  • Measurement Range
  • 0C to 37C
  • Model No
  • PTB-8
  • Core Components
  • Heater, Circulation Pump, Digital Temperature Controller
  • Accuracy
  • 0.1C
  • Frequency
  • 50 Hz
  • Feature
  • Rapid and Uniform Thawing, Overheat Protection, Audible Alarms
  • Automation Grade
  • Semi-Automatic
  • Capacity
  • 8 Plasma Bags (4 Bags x 2 Baskets)
  • Temperature Range
  • Room Temperature to 37C
  • Equipment Materials
  • Stainless Steel Chamber & Outer Body
  • Type
  • Plasma Thawing Bath
  • Usage
  • Hospital, Blood Banks, Laboratory
  • Display Type
  • Digital LED Display
  • Dimension (L*W*H)
  • 550 x 450 x 450 mm
  • Weight
  • Approx 25-28 Kg
  • Basket Material
  • Stainless Steel Basket With Handle
  • Compliance
  • ISO 13485, CE Certified
  • Water Level Sensor
  • Inbuilt Low Water Level Sensor
  • Chamber Volume
  • Approx. 18-20 liters
  • Safety Features
  • Over Temperature Cut-Off, Audio-Visual Alarms
  • Timer
  • Programmable Digital Timer
  • Water Circulation
  • Continuous Water Circulation for Uniform Temperature
  • Heating System
  • Microprocessor Controlled
  • Operating Environment
  • Indoor, Clean Environment
  • Drain System
  • Fitted With Drain Valve
 
 

About Plasma Thawing Bath

Specifications 

  • Display of set value & Process value 
  • Calibration & Validation 
  • O.E.M option availble

 

PLASMA THAWING BATH

 

Micro controller based Plasma Thawing Bath is a tabletop model,for quick thawing of plasma at 37°C.Temperature is controlled by Micro controller based temperature controller.

 

Lasany Cryoprecipitate bath is designed to safely and reliably thaw fresh frozen plasma (FFP) for the recovery of cryoprecipitate ant hemophilic factor (AHF).specially designed trays to ensure safety of plasma bags. Thawing temperature is preset at 4°C and maintained with ± 0.2°C stability.

 

CALIBRATION


The equipment is calibrated with the help of master calibrator,which is certified for its accuracy by Electronics Regional Testing Laboratory (ERTL West) Government of India recognized testing laboratory with traceable refrence to National Physical Laboratories (NPL) .

 

CABINET CONSTRUCTION & REFRIGERATION SYSTEM

 

High density CFC free poly urethane foam insulated cabinet with corrosion resistant stainless steel and white powder coated exterior finish.Cooling is effected by a hermetically sealed compressor of high quality.Complete unit in stainless steel (Inside and outside) is also available.

 

SALIENT FEAUTURES


  • Audio-visual alarm if temperature deviates from preset temperature.
  • Display of set value & Process value.
  • Smooth acrylic tray for internal circulation maintains precise. Temperature uniformity throughout the liquid medium.
  • Rounded corners for better water circulation and uniformity.
  • Formed in place PUF insulation improves temperature stability and energy efficiency.
  • Calibration & Validation.

 

TECHNICAL SPECIFICATION

 

Model No.         LAB-105                      LAB-105A                              

Capacity             16 Bags                      16 Bags

Volume               20 Liters                     20 Liters

Temperature       37°C                           40°C

Accuracy             ± 0.2°C                       ± 0.2°C

Input Voltage       230V AC                    230V AC

Suitable Fluids     Distilled Water        Distilled Water



Precise and Safe Plasma Thawing

The Plasma Thawing Bath incorporates advanced microprocessor controls and programmable digital timers to deliver consistent and safe thawing of plasma products. Multiple safety features such as over-temperature cut-off, audio-visual alarms, and a low water level sensor are in place to protect both users and plasma components during operation.


Durable and Efficient Design

Crafted with stainless steel for both the chamber and outer body, this device withstands rigorous use in medical environments. Its dual basket arrangement accommodates up to eight plasma bags at once, making it ideal for high-throughput blood banks and hospitals seeking both efficiency and reliability.

FAQ's of Plasma Thawing Bath:


Q: How does the Plasma Thawing Bath ensure uniform plasma bag thawing?

A: The Plasma Thawing Bath uses a continuous water circulation system to ensure even temperature distribution within the chamber, preventing hotspots and ensuring all plasma bags are thawed uniformly.

Q: What safety features are included in this plasma thawing system?

A: This system features an over-temperature cut-off, audio-visual alarms, and an inbuilt low water level sensor. These safeguards prevent overheating, alert operators to anomalies, and protect plasma products and personnel.

Q: When and where is this equipment most commonly used?

A: The Plasma Thawing Bath is commonly used in hospitals, blood banks, and laboratory settings with indoor, clean environments where rapid and controlled thawing of plasma is regularly required.

Q: What is the thawing process using this device?

A: To thaw plasma, place plasma bags into the stainless steel baskets and submerge them in the chamber filled with water. Set the desired temperature and timer using the digital controls; the system maintains uniform temperature until the process is complete, after which audible and visual alarms signal completion.

Q: What are the benefits of using this plasma thawing bath?

A: Key benefits include precise temperature control, rapid and uniform thawing, robust safety features, capacity for multiple plasma bags, and compliance with international certifications (ISO 13485, CE), making it reliable for clinical use.

Q: How is the water drained and maintained within the chamber?

A: The bath is equipped with a conveniently located drain valve, allowing quick water removal for cleaning or replacement. Routine cleaning ensures a contaminant-free environment essential for safe thawing.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Laboratories Instruments Equipment Category

Laboratory Stirrer

Laboratory Stirrer

Feature : Variable Speed Control, Corrosion Resistant, Quiet Operation

Type : Overhead Stirrer

Capacity : 2 Ltr

Temperature Range : Ambient to 100 Celsius (oC)

Accuracy : 2 %

Frequency : 50 Hertz (HZ)

Orbital Shaking Incubator

Orbital Shaking Incubator

Feature : Microprocessor Controlled, Speed and Temperature Programmable

Type : Orbital Shaking Incubator

Capacity : 250 L

Temperature Range : Ambient +5C to 60C

Accuracy : 0.5C

Frequency : 50 Hz

Touch Screen Bio Chemistry Analyzer

Touch Screen Bio Chemistry Analyzer

Feature : UserFriendly Touch Interface, Auto Calibration, RealTime Results

Type : Automatic Biochemistry Analyzer

Capacity : 200 tests/hour

Temperature Range : 10C 35C (Operating)

Accuracy : 1% SD

Frequency : 50/60 Hz

Melting Point Apparatus

Melting Point Apparatus

Feature : Fast Heating, High Accuracy, Overheat Protection, Easy Viewing

Type : Laboratory Melting Point Apparatus

Capacity : 4 capillaries

Temperature Range : Ambient to 350C

Accuracy : 1C

Frequency : 50 Hz