Atomic Absporption Spectrophotometer Specification

  • Model No
  • AAS-2404
  • Temperature Range
  • Ambient to 1000°C (Burner)
  • Capacity
  • Single or Double Element Measurement
  • Measurement Range
  • 0.01 ppm to 100 ppm
  • Feature
  • High Sensitivity, Automated Motorized Flame, Safety Interlock, Background Correction
  • Accuracy
  • ± 0.5% reading
  • Core Components
  • Monochromator, Burner Head, Hollow Cathode Lamp, Photomultiplier Detector
  • Automation Grade
  • Semi-Automatic
  • Frequency
  • 50/60 Hz
  • Power Source
  • Electric
  • Voltage
  • 220V AC
  • Equipment Materials
  • Corrosion Resistant Metal Alloy Body
  • Type
  • Flame and Graphite Furnace Combined
  • Usage
  • Laboratory Metal/Element Analysis
  • Display Type
  • Digital LCD Display
  • Dimension (L*W*H)
  • 900 x 540 x 540 mm
  • Weight
  • 45-60 kg (Depends on Model)
  • Lamp Current
  • 0-10 mA Adjustable
  • Safety Features
  • Automatic Gas Cutoff, Burner Head Sensor, Over-Temperature Protection
  • Nebulizer
  • Glass Nebulizer (Standard)
  • Wavelength Range
  • 190 - 900 nm
  • Slit Width
  • 0.2 / 0.4 / 1.0 / 2.0 nm (Selectable)
  • Spectral Bandwidth
  • Adjustable
  • Detection System
  • High Performance Photomultiplier Tube
  • Sample Introduction System
  • Automated Aspiration
  • Flame Type
  • Air-Acetylene, Nitrous Oxide-Acetylene
  • Software
  • Compatible Analysis Software Included
  • Data Output
  • USB, RS232
  • Light Source
  • Hollow Cathode Lamps (4-6 positions)
 
 

About Atomic Absporption Spectrophotometer



Jump on this breathtaking deal with our Reduced Clearance on the Atomic Absorption Spectrophotometer, a pivotal ace for precise laboratory metal and element analysis. Boasting a versatile wavelength range (190900 nm), adjustable spectral bandwidth, and a high-performance photomultiplier tube detection system, this semi-automatic AAS-2404 model guarantees high sensitivity and accuracy (0.5%). The corrosion-resistant alloy body and safety featuresincluding automatic gas cutoff and interlocksensure reliable, long-lasting performance. Complete with automated aspiration and compatible analysis software, this device handles single or double element measurement effortlesslymaking it the ace for laboratories in India.

Versatile Applications Across Laboratories and Industries

The Atomic Absorption Spectrophotometer is ideal for elemental analysis in medical, chemical, pharmaceutical, mining, and agricultural laboratories. Widely used for detecting trace metals in water, soil, food products, and biological samples, its automated aspiration and flame or graphite furnace options enhance versatility. Whether for routine quality control, academic research, or industrial monitoring, its accuracy and adaptability make it indispensable for pivotal analytical tasks.


Certified, Secure Shipping & Swift Delivery

Our spectrophotometer is supplied with certified documentation for compliance and reliability. Each unit is packed with robust, protective materials ensuring safety during transportation, packing, and dispatch. Secure shipping methods guarantee the integrity of the instrument from our facility to your door. Expect prompt delivery timelines so you can begin your analytical processes without delay, with full support from distributors, exporters, and suppliers across India.


FAQs of Atomic Absporption Spectrophotometer:


Q: How does the Atomic Absorption Spectrophotometer ensure user safety during operation?

A: Safety features include automatic gas cutoff, a burner head sensor, temperature protection, and interlocks, providing a secure working environment for laboratory personnel.

Q: What is the process for switching between single and double element measurement?

A: With automated aspiration and selectable hollow cathode lamps, users can easily switch between single or double element modes using the analysis software and digital LCD display.

Q: Where can this spectrophotometer be applied outside traditional chemical laboratories?

A: It can be used in agriculture, mining, pharmaceuticals, environmental testing, and academic research facilities to analyze metals in diverse sample types.

Q: When should I use the flame or graphite furnace mode on the spectrophotometer?

A: Flame mode is suitable for routine elemental analysis, while graphite furnace mode is recommended for trace or low concentration measurements requiring enhanced sensitivity.

Q: What benefits does the adjustable bandwidth and high performance photomultiplier detection system provide?

A: Adjustable bandwidth enables tailored analyses for various elements, while the photomultiplier tube improves detection limits, resulting in more accurate and sensitive measurements.

Q: How is the equipment prepared for transportation and delivery?

A: Each spectrophotometer is securely packed using protective materials and certified packaging methods, ensuring safe and intact arrival during shipping and dispatch.

Tell us about your requirement
product

Price:  

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Scientific Instruments Category

Digital PH, Conductivity & Temperature Meter

Digital PH, Conductivity & Temperature Meter

Usage : Laboratory, Water Treatment, Industrial

Automation Grade : Automatic

Core Components : Electrodes, Microprocessor, Display Unit

Weight : Approx. 2.5 kg

Type : Digital PH, Conductivity & Temperature Meter

Model No : DPT100

Dissolved Oxygen Meters

Dissolved Oxygen Meters

Usage : Lab and Field Use

Automation Grade : Manual

Core Components : Oxygen Sensor, Digital Processor

Weight : 0.6 kg

Type : Portable Meter

Model No : DO960

Pneumatic Troughs

Pneumatic Troughs

Usage : Collection and measurement of gases in laboratory experiments

Automation Grade : Manual

Core Components : Main Trough Body, Shelf/Platform, Cover (optional), Taps and Stoppers (depending on model)

Weight : Approximately 38 kg depending on capacity and material

Type : Laboratory Pneumatic Trough

Model No : PT10/PP, PT12/SS, PT15/GL (examples, varies by manufacturer)

Digital Conductivity Meters

Digital Conductivity Meters

Usage : Measures the electrical conductivity of solutions

Automation Grade : Semiautomatic

Core Components : Conductivity cell, digital meter, electrodes

Weight : Approx 1.2 kg

Type : Benchtop and portable models available

Model No : Varies by manufacturer/model