About Automatic Water Distillation Equipment
Features:- Replaceable Silica Sheathed (Quartz) Heater : The horizontal jacket is fitted with removable silica sheathed heater and screw threaded connectors for ease of cleaning.
- Distillate temperature is approx. between 25° to 45° C which is ensured by an efficient condenser.
- The stand is powder coated for rust free operation and lustrous appearance.
- Cooling water from the condenser is re-circulated into the boiling chamber, hence saving energy.
- Screw Threaded Connectors : These are provided for easy plumbing 8t Installation to avoid any glassware breakage during assembly.
- Fuse is provided for safety in case of voltage fluctuation or short circuit.
- Boiler is provided with Replaceable Constant Level Device for easy draining and cleaning of boiling chamber.
- The front cover is easily removable making the access to the glass parts very easy.
Additional Built-in Safty Features :-- Gate Valve: Conserves cooling water wastage in case of power failure.
- Flow Switch: In-built safety feature for the equipment unit shut off in case of cooling water failure.
- Temperature Switch : The boiler is equipped with a safety temperature switch which shuts off the unit if water level in the boiler falls below the heater, thus saving the glass parts from any damages.
- Level Sensor : It shuts off the distillation equipment if the water level in the boiler falls below the heater.
- Reservoir Level Sensor : This helps in automatic working of the water distillation equipment. Depending on the water level in the reservoir it will automatically switch On/Off the equipment, thus saving energy. (Reservoir can also be provided with a storage capacity of 5 Itr, 10 Itr & 20 Itr made of Borosilicate Glass or polypropylene).
Boresilicate Glass :-
| Model No. | SLCM-20S | SLCM-20D | SLCM-40S | SLCM-40D |
| Output Cap. (approx.) | 2 ltrs/hr | 2 ltrs/hr | 4 ltrs/hr | 4 ltrs/hr |
| Stage | Single Stage | Double Stage | Single Stage | Double Stage |
Distilate Quality :-
| pH | 5.5-6.0 | 6.0-7.0 | 5.5-6.0 | 6.0-7.0 |
| Conductivity pS/cm | 1.0-2.0 | 0.8-1.0 | 1.0-2.0 | 0.8-1.0 |
| Cooling Water Requirement (approx.) | 1.5 Itr/min | 2 Itr/min | 2-3 Itr/min | 2-4 Itr/min |
| Power Rating (Total) | 1.5 KW | 3.0 KW | 3.0 KW | 6.0 KW |
Superior Water Purity for Sensitive ApplicationsOur AWDE-01 distillation unit produces water that is both distilled and pyrogen-free, essential for laboratory and medical environments where purity is paramount. The advanced condensing system and glass boiler ensure contaminant-free results, fully compliant with industry standards.
Safety and Convenience in Every CycleEquipped with automatic switch-off and overheat protection, this table-top unit guarantees safe, unattended operation. The stainless steel structure and Nichrome heating element enhance durability, while the analog display enables straightforward control and monitoring.
Efficient Performance and Low MaintenanceThe AWDE-01 achieves high throughput, producing up to 10 liters per hour with low cooling water consumption (1-2 liters/minute). Its compact design (400 x 250 x 420 mm) fits most lab and medical workspaces, and the automatic operational features minimize user intervention and maintenance.
FAQs of Automatic Water Distillation Equipment:
Q: How does the automatic water distillation equipment ensure water purity?
A: This equipment utilizes a water-cooled condenser and glass boiler to produce distilled, pyrogen-free water. The stainless steel materials and automatic controls minimize contamination, making it suitable for laboratory and medical use.
Q: What types of environments can this equipment be used in?
A: It is designed for a range of applications including laboratory, medical, and some industrial processes where high-purity water is required, thanks to its robust construction and high throughput capacity.
Q: When should the water distillation unit undergo maintenance?
A: Routine maintenance is recommended according to laboratory protocols or after prolonged operation periods to ensure consistent performance. Check and replace core components like the heating element if necessary, especially in high-frequency usage.
Q: Where should the AWDE-01 be installed for optimal operation?
A: Install the equipment on a stable table-top surface in a well-ventilated area with access to electricity and cooling water supply. Its compact dimensions make it suitable for most lab benches or dedicated water purification spaces.
Q: What is the process for distillation in this equipment?
A: The unit automatically heats water with a Nichrome element, vaporizes it, and condenses the steam into purified water using a water-cooled condenser. Automatic switch-off and overheat protection ensure the process runs safely and efficiently.
Q: How do users benefit from the safety features integrated into the distillation unit?
A: Features such as automatic switch-off and overheat protection reduce risks of overheating or accidents, allow safe unattended operation, and protect both the user and the equipment from damage.
Q: What is the cooling water consumption, and how does it affect usage?
A: This model consumes 1-2 liters of cooling water per minute during operation, which helps maintain efficient condensation and guarantees a steady output of distilled water.