  • Measurement Range
  • 960 hPa to 1060 hPa
  • Accuracy
  • 1% of scale
  • Automation Grade
  • Manual
  • Core Components
  • Aneroid capsule, mechanical linkage, pointer dial
  • Equipment Materials
  • Metallic case, glass window, high precision metallic aneroid capsule
  • Type
  • Aneroid Barometer Demonstration Equipment
  • Capacity
  • Standard atmospheric pressure measurement (approx. 9601060 hPa)
  • Dimension (L*W*H)
  • Approx. 150 mm diameter x 50 mm depth
  • Weight
  • Approx. 500 g
  • Markings
  • Clear, black graduations on white background
  • Scale Graduations
  • 1 hPa increments
  • Color
  • Silver with white dial
  • Operation Principle
  • Uses aneroid (no liquid) mechanism
  • Intended Audience
  • Students, teachers, laboratory demonstrators
  • Calibration
  • Factory calibrated, user adjustable
 
 

About Barometer Aneroid Demonstration Equipment

We are committed to manufacture, export and supply our a high quality assortment of Barometer Aneroid Demonstration Equipment. Offered equipment finds its best application in hospitals, research labs and biological industry, hydrology, weather forecasting, etc. for assuming pressure of material where liquid is not involved. This equipment is precisely engineered in sync with the set industry terms and is stringently tested on different parameters. Further, this Barometer Aneroid Demonstration Equipment is available in various specifications at a marginal rate.

Features:

  • Durability

  • Robustness

  • Easy to handle

  • Accurate measurement



Clear and Accurate Pressure Readings

This barometer features black graduations on a white background, allowing students and educators to easily and precisely read atmospheric pressure values in 1 hPa increments. Its clear design aids effective demonstrations and instruction.


Reliable Aneroid Mechanism

With a high-precision metallic aneroid capsule, the device operates without liquids, ensuring clean, safe usage in classrooms and laboratories. Mechanical linkages translate pressure changes into dependable dial movements.


User-Friendly Calibration

Though factory calibrated for immediate use, the barometer allows further user adjustment, accommodating specific demonstration or experimental requirements. This flexibility is helpful for varied environments and instructional needs.

FAQs of Barometer Aneroid Demonstration Equipment:


Q: How does the Barometer Aneroid Demonstration Equipment measure atmospheric pressure?

A: The device uses a high-precision aneroid capsule that flexes with changes in air pressure. This movement is transmitted via mechanical linkage to a pointer dial, allowing manual and precise reading of atmospheric pressure without any liquids.

Q: What is the measurement range and accuracy of this barometer?

A: It measures atmospheric pressure from 960 hPa to 1060 hPa, with graduations every 1 hPa. The accuracy of the readings is within 1% of the scale, making it suitable for educational and laboratory environments.

Q: When should I recalibrate the barometer, and how can this be done?

A: Recalibration is recommended if you notice discrepancies during routine checks or after transportation. The barometer is user-adjustable; instructions for recalibration are typically found in the user manual, or your supplier can provide guidance.

Q: Where is the best environment to use this demonstration equipment?

A: The barometer is ideal for classrooms, science laboratories, and educational demonstrations. Its manual operation and robust construction allow it to be used in various indoor environments, particularly those focusing on atmospheric science education.

Q: What benefits does the aneroid design offer compared to traditional liquid barometers?

A: The aneroid mechanism ensures there are no liquids to spill, making it safer and easier to transport. Its compact, metallic build also enhances durability, while maintaining high precision in pressure measurement.

Q: How should I clean and maintain the barometer?

A: Wipe the metallic case and glass window gently with a soft, dry cloth. Avoid exposing the device to moisture, and store it safely when not in use to prevent dust accumulation and mechanical damage.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Physics instruments Category

Demonstration Induction Coil

Demonstration Induction Coil

Automation Grade : Manual operation

Core Components : Primary coil, secondary coil, iron core, interrupter, condenser, terminals

Feature : Produces highvoltage sparks from lowvoltage DC source, includes spark gap for visual demonstration, interrupted coil operation

Measurement Range : Visual spark gap adjustment up to 4050 mm (approx. corresponding to voltage rise)

Weight : Approx. 23 kg (varies by model)

Dimension (L*W*H) : Approx. 300 x 120 x 170 mm (may vary with make)

Clinical Digital Thermometer

Clinical Digital Thermometer

Automation Grade : Manual

Core Components : LCD Display, Battery, Temperature Sensor

Feature : Auto Power Off, Beeper Alert, Memory Recall

Measurement Range : 32C to 42C

Weight : approx. 12 grams

Dimension (L*W*H) : 130mm x 20mm x 10mm

Rheostats

Rheostats

Automation Grade : Manual

Core Components : Resistive Wire, Sliding Contact

Feature : High Thermal Stability, Smooth Adjustment

Measurement Range : 0 to Max Rated Value (Model Specific)

Weight : Varies with model (Approx. 1 kg to 8 kg)

Dimension (L*W*H) : Model Dependent (e.g., 220 x 100 x 110 mm)

Optical Bench

Optical Bench

Automation Grade : Manual

Core Components : Rods, supports, scale, lens holders, accessories

Feature : Adjustable, sturdy, precise scale, movable riders

Measurement Range : 01000 mm

Weight : Approximately 710 kg

Dimension (L*W*H) : Approx. 1050 x 150 x 150 mm