Back to top
Double Beam Spectrophotometer
Double Beam Spectrophotometer

Double Beam Spectrophotometer

Double Beam Spectrophotometer Specification

  • Capacity
  • 2 ml minimum sample volume
  • Automation Grade
  • Semi-Automatic
  • Core Components
  • Optical system, monochromator, detector, light source
  • Power Source
  • 220V AC main supply
  • Model No
  • SPUV-1200DB
  • Temperature Range
  • Ambient to 45C
  • Voltage
  • 220 V
  • Frequency
  • 50/60 Hz
  • Accuracy
  • 0.003 Abs at 1.0 Abs
  • Feature
  • High precision measurements, rapid scanning, auto zero function
  • Measurement Range
  • 190-1100 nm
  • Equipment Materials
  • High-quality ABS and metal housing
  • Type
  • Double Beam Spectrophotometer
  • Usage
  • UV/VIS analysis, quantitative and qualitative assay
  • Display Type
  • Large LCD Display
  • Dimension (L*W*H)
  • 480 x 380 x 160 mm
  • Weight
  • Approx. 15 kg
 
 

About Double Beam Spectrophotometer

Double Beam Spectrophotometer offered Comes with wavelength range from 190-1100 nm, spectral bandwidth of 1 nm and working mode of T,A,C,E. Also featuring double beam based optical system, it can deliver slow, medium and fast scanning speeds as per he requirements. Further for more efficient performance, the system is capable of delivering photometric accuracy of + 0.3% T (0-100% T) & +0.002 A (0-0.1 A), photometric reproducibility of < 0.15 % T, stability of < 0.001A/h (at 500 nm, after warming up). Some of the other standard features of the system include 6 inches high light blue LCD display support, options of glass cells, quartz cells, fuse, instrument cover, software CD and RS 232 cable among others.

Technical Specification:-


Wavelength Range

190-1100 nm

Spectral Bandwidth

1 nm

Working Mode

T,A,C,E

Optical System

Double beam

Scanning Speed

Fast / Medium / Slow

Photometric Range

-0.3 - 3.5 A, 0 to 220 %T

Wavelength Accuracy

+0.3 nm

Wavelength Reproducibility

< 0.10 nm

Photometric Accuracy

+ 0.3% T (0-100% T)
+0.002 A (0-0.1 A)

Photometric Reproducibility

< 0.15 % T

Stray Light

< 0.1% T (Nal. 220nm, NaNO2 340 nm)

Baseline Flatness

+ 0.002 A

Stability

< 0.001A/h (at 500 nm, after warming up)

Noise

+0.001A (at 500 nm, after warming up)

Detector

Dual Silicon Photodiode

Display

6 inches high light blue LCD

Power

AC:220V + 10%, 50 Hz.

Dimensions

630 x 470 x 210 mm

Weight

26 Kg

Glass Cells

16 No.

Quartz Cells

4 Nos.

Fuse

3 Nos.

Instrument Cover

1 No.

Software CD

1 No.

RS 232 Cable

1 No.

Operation Manual

1 No.






High Accuracy and Excellent Stability

Benefit from superior accuracy (0.003 Abs at 1.0 Abs) and stability ( 0.001 A/h @ 500 nm), ensuring reliable and reproducible results for every measurement. The optical system and silicon photodiode array detector minimize noise ( 0.001 A), making the SPUV-1200DB ideal for sensitive assays and demanding research environments.


User-Friendly Features and Flexible Operation

Designed with semi-automatic operation and a large LCD display, this spectrophotometer simplifies workflows in academic, pharmaceutical, and industrial labs. Its Windows-compatible software, with robust data export and graphing capabilities, supports efficient analysis, while optional automation and a wide sample volume range accommodate diverse application needs.


Durable Construction for Rigorous Applications

Constructed with high-quality ABS and metal housing, the SPUV-1200DB withstands intensive laboratory use. It operates within an ambient to 45C temperature range and features cost-effective lamps (2000 h deuterium, 3000 h tungsten halogen), ensuring long-term, dependable service for distributors, manufacturers, and end-users alike.

FAQs of Double Beam Spectrophotometer:


Q: How does the double beam feature benefit UV/VIS analysis in the SPUV-1200DB?

A: The double beam design allows simultaneous measurement of sample and reference beams, reducing baseline drift and compensating for fluctuations. This improves accuracy and stability, essential for quantitative and qualitative UV/VIS assays in research and industry.

Q: What types of samples and volumes can the spectrophotometer analyze?

A: The SPUV-1200DB accommodates sample volumes from 0.5 to 3.5 ml, depending on cuvette size, with a minimum of 2 ml recommended. It is suitable for a wide range of solutions typically encountered in chemical, pharmaceutical, and academic laboratories.

Q: When should the lamps be replaced, and what is their expected lifespan?

A: The deuterium lamp provides up to 2000 hours, while the tungsten halogen lamp offers around 3000 hours of use. Replacement is recommended near the end of their rated lifespans or when light intensity decreases, ensuring consistent measurement performance.

Q: Where can the SPUV-1200DB spectrophotometer be used effectively?

A: This model performs excellently in research institutes, academic labs, pharmaceutical analysis, and industrial testing facilities across India and globally, thanks to its robust construction and precise analytical capabilities.

Q: What is the process for exporting data and creating graphs with this spectrophotometer?

A: Using the included Windows-compatible software, users can export measurement data via USB or RS-232 and leverage built-in graphing features for immediate visualization or reporting, streamlining the analysis workflow.

Q: How does the automatic cuvette changer enhance laboratory efficiency?

A: The optional 4-position automatic cuvette changer enables rapid, sequential measurement of multiple samples, reducing manual intervention and improving throughput, especially during high-volume testing or batch analysis.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Double Beam UV-VIS Spectrophotometer Category

UV- Visible Software Spectrophotometer

UV- Visible Software Spectrophotometer

Dimension (L*W*H) : 470 mm x 360 mm x 160 mm

Power Source : Electric powered

Model No : UV1800

Temperature Range : Ambient to 45C

Core Components : Light source, monochromator, detector, display module, software

Equipment Materials : Corrosionresistant alloy frame, optical grade glass

Double Beam UV-VIS Spectrophotometers

Double Beam UV-VIS Spectrophotometers

Dimension (L*W*H) : 480 mm x 420 mm x 210 mm

Power Source : 220V AC

Model No : UV2600

Temperature Range : Ambient (Nonheating)

Core Components : Deuterium Lamp, Tungsten Halogen Lamp, Double Beam Optics, Grating Monochromator

Equipment Materials : Aluminum Body with Powder Coating, Optical Glass, Premium Plastic

Double Beam UV Visible Spectrophotometer

Double Beam UV Visible Spectrophotometer

Dimension (L*W*H) : 550 mm x 450 mm x 220 mm

Power Source : AC Mains

Model No : UVS2002DB

Temperature Range : Ambient, 5C to 45C operating

Core Components : UV lamp, Cuvette Holder, Photomultiplier Detector, Optical System

Equipment Materials : Highgrade ABS plastic body, Quartz optics

Microprocessor UV / VIS Spectrophotometer (Double Beam)

Microprocessor UV / VIS Spectrophotometer (Double Beam)

Dimension (L*W*H) : 630 470 210 mm

Power Source : AC mains

Model No : UV2000DB

Temperature Range : Ambient (10C40C)

Core Components : Microprocessor, Deuterium lamp, Tungsten lamp, Optical system

Equipment Materials : ABS structure, highquality optical glass, and metal components