Hydrometer Specification

  • Core Components
  • Calibrated Glass Tube, Weighted Bulb
  • Power Source
  • Manual (No Power Required)
  • Feature
  • Easy to Read Scale, Corrosion Resistant
  • Accuracy
  • 0.001 g/cm3
  • Temperature Range
  • 0C to 60C
  • Measurement Range
  • 0.98 to 1.09 specific gravity
  • Automation Grade
  • Manual
  • Capacity
  • 0.98 g/cm3 to 1.09 g/cm3
  • Model No
  • HYDRO-001
  • Equipment Materials
  • Glass
  • Type
  • Laboratory Hydrometer
  • Usage
  • Measurement of liquid density/specific gravity
  • Display Type
  • Glass Scale
  • Dimension (L*W*H)
  • Length: 250 mm; Diameter: 18 mm
  • Weight
  • Approx 50 grams
  • Application
  • Chemical, Laboratory, Educational, Industrial
  • Calibration
  • Factory Calibrated
  • Storage Temperature
  • Room Temperature (10C to 35C)
  • Packing Type
  • Individual Protective Case
  • Shelf Life
  • Indefinite with proper handling
  • Reading Scale
  • Graduated Markings, Black on White
  • Immersion Depth
  • Calibrated for full immersion
  • Cleaning Method
  • Rinse with distilled water after use
  • Complies With
  • ASTM Standards
 
 

About Hydrometer

Our range of thermo hydro meter are used for monitoring multiple factors that can lead to mold, dust mites & bacteria. These are incorporated with built-in visual and audible alarm alerts the end user to mold growth conditions.


Features :


  • Measures relative humidity, dew point and room temperature
  • Equipped with precision hygrometer
  • Min/Max values with reset feature


Highly Accurate Density Measurements

Engineered for precision, the HYDRO-001 hydrometer provides reliable readings with an accuracy of 0.001 g/cm3. Its glass scale and full-immersion calibration enable consistent, dependable results for all users, making it a preferred choice across educational, laboratory, and industrial settings.


Durable and User-Friendly Design

Manufactured from high-grade, corrosion-resistant glass, this hydrometer requires no power source, functioning entirely through manual immersion. The black-on-white scale ensures clear visibility, while the included protective case helps prevent breakage during storage or transport.


Simple Maintenance and Compliance

After each use, the hydrometer only needs to be rinsed with distilled water, ensuring longevity and maintenance of accuracy. The HYDRO-001 meets ASTM standards, supporting quality assurance protocols for professionals in India and global markets.

FAQ's of Hydrometer:


Q: How should I properly use the HYDRO-001 Laboratory Hydrometer?

A: To use the HYDRO-001 hydrometer, gently place it into the liquid sample at room temperature (10C to 35C), ensuring it is fully immersed as calibrated. Read the specific gravity from the graduated black-on-white scale at the liquid's surface level.

Q: What process should I follow for cleaning and storing the hydrometer?

A: After each use, rinse the hydrometer thoroughly with distilled water to prevent residue buildup and maintain accuracy. Once dry, store it in its individual protective case to safeguard against accidental damage.

Q: When is the HYDRO-001 most beneficial for laboratory or industrial applications?

A: This hydrometer is most beneficial whenever accurate measurements of liquid density or specific gravity are required-such as during chemical analysis, formulation verification, or educational demonstrations within the 0.98 to 1.09 g/cm3 range.

Q: Where can the HYDRO-001 be used safely and efficiently?

A: HYDRO-001 is suitable for use in chemical laboratories, educational classrooms, industrial quality control departments, and research facilities provided ambient temperature remains between 0C and 60C.

Q: How does factory calibration and ASTM compliance benefit the user?

A: Factory calibration ensures optimal measurement accuracy, while ASTM standard compliance guarantees that the hydrometer meets industry-recognized benchmarks, enhancing reliability and acceptance in professional and academic environments.

Q: What are the main components and features of the HYDRO-001 hydrometer?

A: The hydrometer comprises a calibrated glass tube, a weighted bulb for stability, a corrosion-resistant body, and a clearly printed scale. Manual operation and the absence of power requirements make it highly portable and easy to use.

Tell us about your requirement
product

Price:  

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Scientific Instruments Category

Digital Polarimeter

Digital Polarimeter

Temperature Range : 0°C to 50°C

Dimension (L*W*H) : 500 x 135 x 220 mm

Accuracy : ±0.01°

Equipment Materials : Stainless Steel, Glass, ABS Plastic

Feature : Automatic Zero Setting, Digital Readout, UserFriendly Interface

Power Source : AC Electric

Microprocessor Viscometer

Microprocessor Viscometer

Temperature Range : 0°C to 60°C

Dimension (L*W*H) : 350mm x 280mm x 450mm

Accuracy : ±1% FS

Equipment Materials : Stainless Steel & ABS Body

Feature : Automated measurement, easy calibration

Power Source : Electric

Digital Photo Colorimeters

Digital Photo Colorimeters

Temperature Range : 0°C 50°C

Dimension (L*W*H) : 245 x 210 x 110 mm

Accuracy : ±0.02 OD

Equipment Materials : Highgrade plastic body, corrosionresistant optical components

Feature : Direct digital readout, auto zero adjustment, high accuracy, long lifespan

Power Source : 230V AC mains or builtin rechargeable battery

All Quartz Double Distillation

All Quartz Double Distillation

Temperature Range : Ambient to 400°C

Dimension (L*W*H) : 450 × 250 × 600 mm

Accuracy : High purity distillate, Conductivity less than 1 µS/cm

Equipment Materials : High purity fused quartz glass

Feature : Automatic shutoff, High chemical resistance, Low water feed cutoff

Power Source : Electric