Back to top
All Quartz Double Distillation
All Quartz Double Distillation

All Quartz Double Distillation

All Quartz Double Distillation Specification

  • Model No
  • AQDD-2
  • Measurement Range
  • 0.5 to 2 liters/hr
  • Accuracy
  • High purity distillate, Conductivity less than 1 µS/cm
  • Automation Grade
  • Semi-automatic
  • Core Components
  • Quartz Boiler, Quartz Condenser, Heater, Interlocking System
  • Frequency
  • 50/60 Hz
  • Temperature Range
  • Ambient to 400°C
  • Voltage
  • 220–240 V
  • Capacity
  • 2 liters/hr
  • Feature
  • Automatic shutoff, High chemical resistance, Low water feed cutoff
  • Power Source
  • Electric
  • Equipment Materials
  • High purity fused quartz glass
  • Type
  • All Quartz Double Distillation Unit
  • Usage
  • Laboratory/Research/Pharmaceutical Applications
  • Display Type
  • Analog
  • Dimension (L*W*H)
  • 450 × 250 × 600 mm
  • Weight
  • Approx. 15 kg
  • Installation Type
  • Table Top
  • Boiling Chamber Capacity
  • 2 Liters
  • Noise Level
  • Low
  • Water Quality Output
  • Pyrogen-free & Metal-free Water
  • Applications
  • Medical, Pharmaceutical, Laboratories
  • Operating Pressure
  • Atmospheric Pressure
  • Distillation Type
  • Double Stage (Quartz to Quartz)
  • Maintenance
  • Tool-free Cleaning - No Metallic Parts
  • Heating Element Material
  • Quartz Immersion Heater
  • Feed Water Type
  • Treated Tap Water
  • Safety Features
  • Dry Run Protection, Over-temperature Cut-off
  • Condenser Cooling
  • Quartz Spiral Condenser
  • Cooling Water Requirement
  • 1-2 Liters/min
 
 

About All Quartz Double Distillation


All Quartz Double Distillation

ParametersValues
Specific Conductivity0.1-0.5 |js/cm
Biological Activity (distillate quality)Pyrogen Free
pH6.0-7.0
Organic MatterNil
Total Solids0.1 mg/ltr
Silica<0.01 mg/ltr

** All the parameters are under Standard Test Conditions,Please test the distilled water before use. 

Advantages :-

  • Easy cleaning of the first boiler since it can be dismantled from the assembly.
  • Ease of interchangeability as it is provided with Ball & Socket joint.
  • Boiler & condenser have larger boiling space resulting in balanced boiling & improved quality of distillate.
  • Compact and easy to install.

Technical Specifications :-

Model No.Output Capacity ( Approx.)Power Rating (Total)Cooling water Consumption (Approx.)
LTDD-15AQ1.5ltr/hr3 KW50 ltrs/hr
LTDD-25AQ2.5ltr/hr5KW70 ltrs/hr
LTDD-35AQ3.5ltr/hr7KW90 ltrs/hr
LTDD-40AQ4.0ltr/hr8KW120 ltrs/hr
LTDD-50AQ5.0ltr/hr9KW150 ltrs/hr


High Purity Distillation for Sensitive Applications

This double stage all-quartz distillation unit is engineered for producing high-purity water essential for medical, pharmaceutical, and laboratory settings. With a conductivity below 1 S/cm, the unit guarantees pyrogen-free and metal-free water, making it ideal for procedures requiring the strictest purity standards.


Robust Safety and Maintenance Features

Safety comes first with dry run protection, over-temperature cut-off, and automatic shutoff. Its innovative, tool-free cleaning system and all-quartz construction eliminate metallic contamination and simplify upkeep, allowing hassle-free daily use even in demanding environments.


Efficient and User-Friendly Operation

Operating at atmospheric pressure, this tabletop unit distills up to 2 liters of water per hour while maintaining low noise. An analog display assists monitoring, and with minimal installation and maintenance needs, the quartz spiral condenser ensures effective cooling for consistent output.

FAQs of All Quartz Double Distillation:


Q: How does the All Quartz Double Distillation Unit ensure water purity?

A: The unit employs a double stage distillation process using only high purity fused quartz components. This design prevents contact with metals or contaminants, delivering pyrogen-free and metal-free distilled water suitable for critical laboratory and medical applications.

Q: What is the recommended feed water type and cooling water requirement?

A: For optimum operation, the unit requires treated tap water as feed and a cooling water supply of 12 liters per minute. This helps maintain optimal temperatures and supports the effectiveness of the quartz spiral condenser.

Q: When should the units maintenance or cleaning be performed?

A: The tool-free cleaning system and absence of metallic parts allow for easy maintenance. Regular cleaning should be scheduled after each use or as per your laboratory protocol, ensuring the production of high-purity water and reliable performance.

Q: Where is the ideal installation location for this distillation unit?

A: Designed for tabletop use, the unit fits conveniently in laboratory, research, or pharmaceutical workspaces. It is compact, measuring 450 250 600 mm, and weighs approximately 15 kg, making it easy to position near electrical and water connections.

Q: What safety measures are incorporated in this distillation equipment?

A: Safety features include dry run protection, over-temperature cut-off, automatic shutoff, and low water feed cutoff. The interlocking system and all-quartz construction provide added safeguards during operation, protecting both users and equipment.

Q: How does the automatic shutoff and interlocking system benefit users?

A: The automatic shutoff and interlocking system minimize risks by powering down the unit in case of overheating, lack of water, or system faults. This not only prolongs equipment lifespan but also enhances operational safety and reliability.

Q: What are the benefits of using a quartz immersion heater and spiral condenser?

A: The quartz immersion heater ensures uniform heating without leaching contaminants, while the quartz spiral condenser offers high chemical resistance and efficient cooling, preserving the integrity and purity of the distilled water produced.

Tell us about your requirement
product

Price:  

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Scientific Instruments Category

Water Still with Silica Sheathed Heater

Water Still with Silica Sheathed Heater

Dimension (L*W*H) : 450 x 230 x 370 mm

Weight : Approx. 8 Kg

Model No : WSSS4

Equipment Materials : Borosilicate Glass, Silica Sheathed Heater, Stainless Steel Clamps

Usage : Water Distillation for Laboratory Use

Type : Laboratory Water Still

Liquid Chromatography System

Liquid Chromatography System

Dimension (L*W*H) : 550 mm x 450 mm x 370 mm

Weight : Approx 25 kg

Model No : LCS500

Equipment Materials : Corrosionresistant stainless steel and chemically resistant polymers

Usage : Laboratory analysis of liquid samples, purification, and separation

Type : Automated Liquid Chromatography System

Atomic Absorption Spectrophotometer

Atomic Absorption Spectrophotometer

Dimension (L*W*H) : 680 x 540 x 470 mm

Weight : Approx. 45 kg

Model No : AAS4

Equipment Materials : Corrosionresistant, Stainless Steel Housing

Usage : Elemental Analysis in Laboratories

Type : Atomic Absorption Spectrophotometer

Atomic Absporption Spectrophotometer

Atomic Absporption Spectrophotometer

Dimension (L*W*H) : Approx. 1100 x 420 x 500 mm

Weight : Approx. 65 kg

Model No : AA6300

Equipment Materials : Corrosionresistant alloy and stainless steel

Usage : Elemental analysis in laboratories

Type : Atomic Absorption Spectrophotometer