Back to top
Precision Digital Melting Point System
Precision Digital Melting Point System

Precision Digital Melting Point System

Precision Digital Melting Point System Specification

  • Capacity
  • 3 capillaries per run
  • Feature
  • Accurate temperature control, Digital readout, Programmable heating rate, Inbuilt fan
  • Power Source
  • Electric
  • Temperature Range
  • Ambient to 320°C
  • Core Components
  • PID Microprocessor controller, Capillary holder
  • Frequency
  • 50/60 Hz
  • Voltage
  • 220-240V AC
  • Automation Grade
  • Semi-automatic
  • Model No
  • MP-300D
  • Accuracy
  • ±0.5°C
  • Measurement Range
  • Up to 320°C
  • Equipment Materials
  • Powder coated metal with glass viewing window
  • Type
  • Digital Melting Point System
  • Usage
  • Laboratory melting point determination
  • Display Type
  • Digital LCD display
  • Dimension (L*W*H)
  • 200 x 175 x 150 mm
  • Weight
  • Approx. 5 kg
  • Capillary Tube Size
  • 1.4 mm outer diameter, open at one end
  • Calibration
  • Factory pre-calibrated, user calibration option
  • Safety Features
  • Automatic cut-off at over-temperature, Audio/visual alarms
  • Compliance
  • Meets ISO and ASTM standards for melting point determination
  • Heating Rate
  • Selectable: 0.5°C, 1.0°C, 1.5°C per min
  • Sample Viewing
  • Integrated magnifying lens with clear viewing window and LED illumination
  • Accessory Kit
  • Includes 100 capillary tubes and cleaning brush
  • Data Output
  • USB data output for documentation
  • Cooling System
  • Integrated fan-assisted cooling
  • Ambient Operating Conditions
  • 10°C to 35°C, non-condensing environment
 
 

About Precision Digital Melting Point System

Digital Automatic Melting Point Apparatus is designed for quick and accurate detection of melting point. Feature packed & easy to use, this is an indispensable bench top tool. This equipment has an arrangement to hold the capillary containing the sample in uniformly heating media. the temperature is indicated on a digital display readable in 1.0 C. At the point, whn the sample melts, the heating is automatically cut-off and the digital display showing the temperature remains on the indicator till it is cleared. No Silicon oil or other bath is required as heating media. Range 2.0 C above room temperature to 350 C.

 

Specifications


Display

Digital 3 1/2 Digit, Bright LED

Accuracy

1%

Operation

Fully Automatic

Dimensions

L 405 x B 360 x H 235 mm (approx)

Weight

5 Kg (approx.)

Power

230V + 10?, 50Hz

Accessories

Capillary Tube - 100 No. 
Cleaning Tool - 1 No.

 

Salient Features of the product are

  • Fully Automatic
  • Latest Technology
  • Range up to 350oC
  • Highly Accurate
  • No Silicon Oil/Heating Media Required


Advanced Temperature Control and Safety

The MP-300D incorporates a PID microprocessor controller for precise temperature regulation, offering accuracy of 0.5C. User-selectable heating rates allow tailored analysis, while integrated safety features such as automatic cut-off and real-time alarms safeguard against overheating and operational errors.


User-Friendly Viewing and Documentation

Clear sample observation is facilitated with a built-in magnifying lens, LED illumination, and a glass viewing window. The system allows efficient data documentation via USB output, meeting laboratory reporting requirements and simplifying record management for compliance and quality control.


Convenient Calibration and Efficient Cooling

Factory pre-calibrated, the MP-300D also offers user calibration options for sustained accuracy. The integrated fan-assisted cooling system accelerates sample turnaround, making it ideal for laboratories that require reliable and repeatable melting point determinations.

FAQs of Precision Digital Melting Point System:


Q: How can I calibrate the Precision Digital Melting Point System, and is user calibration supported?

A: The system comes factory pre-calibrated, ensuring immediate accuracy upon installation. Users can also perform calibration using the built-in calibration option for routine checks or adjustments, supporting consistent performance over time.

Q: What process does the system use for melting point determination, and how does it ensure accuracy?

A: The MP-300D utilizes selectable programmable heating rates controlled by a PID microprocessor for precise thermal management. Accurate temperature measurement is achieved with a digital LCD display and a high-quality capillary holder, delivering reliable melting point results within 0.5C.

Q: When should I use the integrated cooling system during operation?

A: The fan-assisted cooling system is designed for use after sample analysis, rapidly bringing the instrument back to ambient temperatures and enabling quicker successive tests, thereby improving laboratory throughput.

Q: Where is data from melting point tests stored or exported for record keeping?

A: Test data can be exported directly via the built-in USB port, allowing easy transfer to computers or laboratory information management systems for documentation, compliance, or further analysis.

Q: What benefits does the included accessory kit provide for routine use?

A: The accessory kit includes 100 precision capillary tubes and a cleaning brush, ensuring you have essential supplies for multiple runs, reducing downtime between tests and facilitating instrument maintenance.

Q: How does the system enhance sample viewing during melting point analysis?

A: An integrated magnifying lens and clear glass window, combined with LED illumination, provide optimal visibility of capillary tubes and samples, allowing accurate and detailed observation of melting behaviors.

Tell us about your requirement
product

Price:  

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Scientific Instruments Category

Physics Lab Experiment Kits

Physics Lab Experiment Kits

Capacity : Various (set includes multiple experiment modules with different capacities)

Feature : Modular kit, easy to assemble, suitable for STEM education

Power Source : AC mains or battery (varies by experiment)

Temperature Range : 10°C to 110°C

Equipment Materials : Highgrade plastic, aluminum, glass, copper, and iron components

Weight : Approx. 4.5 kg (complete kit)

Separating Funnel

Separating Funnel

Capacity : 250 ml

Feature : Chemical resistant, tight sealing

Power Source : Manual

Temperature Range : Ambient (Not for heating/cooling)

Equipment Materials : Borosilicate Glass

Weight : Approx. 150 grams