PCR Thermal Cycler Specification

  • Voltage
  • 220 V
  • Capacity
  • 96 wells (0.2 ml per well)
  • Temperature Range
  • 4°C to 99.9°C
  • Power Source
  • AC electricity
  • Model No
  • PCR-TC96
  • Automation Grade
  • Semi-automatic
  • Accuracy
  • ±0.1°C
  • Core Components
  • Peltier heating and cooling system, touchscreen controller
  • Frequency
  • 50/60 Hz
  • Feature
  • Gradient function, rapid heating/cooling, built-in data storage
  • Measurement Range
  • 0.1°C increments
  • Equipment Materials
  • ABS plastic, stainless steel heating block
  • Type
  • Gradient PCR Thermal Cycler
  • Usage
  • Gene amplification, molecular biology research
  • Display Type
  • LCD touch screen
  • Dimension (L*W*H)
  • 380 x 280 x 230 mm
  • Weight
  • Approximately 10 kg
  • Cooling Rate
  • Up to 3C/sec
  • USB Connectivity
  • Yes
  • Safety Features
  • Over-temperature protection, password lock
  • Lid Temperature
  • 30-110C adjustable
  • User Programs
  • Multiple programmable protocols
  • Heating Rate
  • Up to 4C/sec
  • Humidity Control
  • Automatic
  • Software Compatibility
  • Windows and Mac
  • Ramp Rate
  • User programmable
  • Block Uniformity
  • 0.2C across wells
  • Data Storage
  • Internal memory and USB export
  • Sample Volume Range
  • 10-100 l
  • Noise Level
  • 40 dB
 
 

PCR Thermal Cycler About

Salient Features

 

  • Adjustable pressure hot lid to prevent volatilizing and dewing.
  • Heat lid with pressure alarm device, to prevent damaging test tube by too much pressure.
  • Convenient and flexible module replacement mode.
  • Innovative module wire socket design achieves module replacement without wire.
  • The unique left-right design for amplification area and operating area.
  • Colored and wide screen displaying Multiple details.
  • Perform  20000 times non-breakdown operation.

 

Technical Specification:-

 

Block Capacity

61 x 0.2 ml or 36 x 0.5 ml

Temperature Range

4°C to 99°C

Max. Heating Rate

<2.5 °C/s

Max. Cooling Rate

<2.5°C/s

Temperature display accuracy

0.1°C

Accuracy

< + 2.5°C/s

Temperature Fluctuation

< + 0.1°C

Uniformity

95°C h< + 0.5°C (20 seconds later)

20°C ~ 72°C h < + 0.3°C (20 seconds later)

Max. Program unit

9

Max. Cycle Step

9

Max. Cycle No.

99

Max. constant temperature

59m59s

Stores Program No.

99h59m

Stored Program No.

100

Dimension

370 mm (L) x 249 mm (W) x 180 mm (H)

Weight

5 Kg




Superior Performance for Gene Amplification

Designed for molecular biology laboratories, the PCR-TC96 Gradient PCR Thermal Cycler combines rapid heating and cooling capabilities with highly accurate temperature control (0.1C). Its gradient function allows for protocol optimization across the temperature range of 4C to 99.9C, streamlining workflows and producing reliable amplification results.


Flexible and User-Friendly Operation

This thermal cycler features programmable protocols, an intuitive LCD touch screen, and multiple data storage options. Researchers can easily customize protocols and export results through USB connectivity, while automatic humidity control maintains optimal sample conditions for consistent experimentation.


Emphasis on Security and Safety

Built-in safety features such as over-temperature protection and password lock reduce risks during operation. The durable design, using ABS plastic and stainless steel, ensures longevity even in high-throughput lab environments, supporting semi-automatic operation and precise measurement increments for dependable everyday use.

FAQs of PCR Thermal Cycler:


Q: How is the temperature ramp rate adjusted on the PCR-TC96 Gradient PCR Thermal Cycler?

A: The ramp rate, determining how quickly the cycler heats or cools, can be programmed by the user via the LCD touch screen interface. This allows precise control between cycles for enhanced amplification accuracy and protocol flexibility.

Q: What types of data storage and export options does this PCR thermal cycler provide?

A: The PCR-TC96 includes built-in internal memory for storing user protocols and run data. Data can also be exported via USB drive, ensuring convenient backup and transfer to Windows or Mac systems for further analysis.

Q: When is automatic humidity control utilized during PCR runs?

A: Automatic humidity control is active throughout the run, preserving sample integrity by preventing evaporation and condensation episodes. This is particularly beneficial during lengthy or high-temperature protocols.

Q: Where can the PCR-TC96 thermal cycler be most effectively used?

A: This model is suitable for molecular biology laboratories engaged in gene amplification, diagnostic research, and educational settings. Its compact design and robust build (ABS plastic, stainless steel) mean it fits well on benchtops and withstands everyday lab use.

Q: What processes does the gradient function support, and how does it benefit users?

A: Gradient functionality allows users to test multiple annealing temperatures simultaneously across the 96-well block. This streamlines protocol optimization, saving time and increasing the likelihood of achieving ideal amplification conditions for diverse DNA templates.

Q: How does the safety system protect both the operator and the samples?

A: The thermal cycler integrates over-temperature protection, which automatically halts operation if unsafe conditions arise. Additionally, a password lock prevents unauthorized access, safeguarding both the instrument and sensitive experimental data.

Q: What is the recommended sample volume range for optimal PCR results on this device?

A: The PCR-TC96 is optimized for sample volumes between 10 and 100 l per well, ensuring flexibility for varied molecular biology applications and supporting up to 96 reactions simultaneously in standard 0.2 ml tubes.

Tell us about your requirement
product

Price:  

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Scientific Instruments Category

Dissolved Oxygen Meters

Dissolved Oxygen Meters

Capacity : 020 mg/L

Weight : 0.6 kg

Type : Portable Meter

Temperature Range : 0°C to 50°C

Equipment Materials : ABS Plastic Body

Model No : DO960

Microprocessor Flame Photometer

Microprocessor Flame Photometer

Capacity : Upto 4 elements (Na, K, Ca, Li) can be measured sequentially or singly

Weight : Approx. 8 kg

Type : Digital Flame Photometer

Temperature Range : Optimum operating at ambient to 40°C

Equipment Materials : Corrosion resistant powder coated mild steel

Model No : Microprocessor Flame Photometer 1381

Eliza Washer Card Reader

Eliza Washer Card Reader

Capacity : Single card access, supports up to 50,000 card data storage

Weight : Approx. 250g

Type : Card Reader for Washer Control

Temperature Range : 10°C to 70°C

Equipment Materials : ABS Plastic, Electronic PCB

Model No : ElizaCR100

Digital Polarimeter

Digital Polarimeter

Capacity : 2 ml—200 ml (Sample Tube) / 8200 mm (Tube Length)

Weight : Approx. 68 kg

Type : Digital Polarimeter

Temperature Range : 0°C to 50°C

Equipment Materials : Stainless Steel, Glass, ABS Plastic

Model No : DP20