Back to top
PCR Thermal Cycler
PCR Thermal Cycler

PCR Thermal Cycler

PCR Thermal Cycler Specification

  • Model No
  • PCR-TC96
  • Capacity
  • 96 wells (0.2 ml per well)
  • Measurement Range
  • 0.1°C increments
  • Temperature Range
  • 4°C to 99.9°C
  • Voltage
  • 220 V
  • Accuracy
  • ±0.1°C
  • Core Components
  • Peltier heating and cooling system, touchscreen controller
  • Feature
  • Gradient function, rapid heating/cooling, built-in data storage
  • Automation Grade
  • Semi-automatic
  • Power Source
  • AC electricity
  • Frequency
  • 50/60 Hz
  • Equipment Materials
  • ABS plastic, stainless steel heating block
  • Type
  • Gradient PCR Thermal Cycler
  • Usage
  • Gene amplification, molecular biology research
  • Display Type
  • LCD touch screen
  • Dimension (L*W*H)
  • 380 x 280 x 230 mm
  • Weight
  • Approximately 10 kg
  • Block Uniformity
  • 0.2C across wells
  • Ramp Rate
  • User programmable
  • USB Connectivity
  • Yes
  • Lid Temperature
  • 30-110C adjustable
  • Cooling Rate
  • Up to 3C/sec
  • Software Compatibility
  • Windows and Mac
  • Heating Rate
  • Up to 4C/sec
  • Sample Volume Range
  • 10-100 l
  • User Programs
  • Multiple programmable protocols
  • Humidity Control
  • Automatic
  • Safety Features
  • Over-temperature protection, password lock
  • Data Storage
  • Internal memory and USB export
  • Noise Level
  • 40 dB
 
 

About PCR Thermal Cycler

Salient Features

 

  • Adjustable pressure hot lid to prevent volatilizing and dewing.
  • Heat lid with pressure alarm device, to prevent damaging test tube by too much pressure.
  • Convenient and flexible module replacement mode.
  • Innovative module wire socket design achieves module replacement without wire.
  • The unique left-right design for amplification area and operating area.
  • Colored and wide screen displaying Multiple details.
  • Perform  20000 times non-breakdown operation.

 

Technical Specification:-

 

Block Capacity

61 x 0.2 ml or 36 x 0.5 ml

Temperature Range

4°C to 99°C

Max. Heating Rate

<2.5 °C/s

Max. Cooling Rate

<2.5°C/s

Temperature display accuracy

0.1°C

Accuracy

< + 2.5°C/s

Temperature Fluctuation

< + 0.1°C

Uniformity

95°C h< + 0.5°C (20 seconds later)

20°C ~ 72°C h < + 0.3°C (20 seconds later)

Max. Program unit

9

Max. Cycle Step

9

Max. Cycle No.

99

Max. constant temperature

59m59s

Stores Program No.

99h59m

Stored Program No.

100

Dimension

370 mm (L) x 249 mm (W) x 180 mm (H)

Weight

5 Kg




Superior Performance for Gene Amplification

Designed for molecular biology laboratories, the PCR-TC96 Gradient PCR Thermal Cycler combines rapid heating and cooling capabilities with highly accurate temperature control (0.1C). Its gradient function allows for protocol optimization across the temperature range of 4C to 99.9C, streamlining workflows and producing reliable amplification results.


Flexible and User-Friendly Operation

This thermal cycler features programmable protocols, an intuitive LCD touch screen, and multiple data storage options. Researchers can easily customize protocols and export results through USB connectivity, while automatic humidity control maintains optimal sample conditions for consistent experimentation.


Emphasis on Security and Safety

Built-in safety features such as over-temperature protection and password lock reduce risks during operation. The durable design, using ABS plastic and stainless steel, ensures longevity even in high-throughput lab environments, supporting semi-automatic operation and precise measurement increments for dependable everyday use.

FAQs of PCR Thermal Cycler:


Q: How is the temperature ramp rate adjusted on the PCR-TC96 Gradient PCR Thermal Cycler?

A: The ramp rate, determining how quickly the cycler heats or cools, can be programmed by the user via the LCD touch screen interface. This allows precise control between cycles for enhanced amplification accuracy and protocol flexibility.

Q: What types of data storage and export options does this PCR thermal cycler provide?

A: The PCR-TC96 includes built-in internal memory for storing user protocols and run data. Data can also be exported via USB drive, ensuring convenient backup and transfer to Windows or Mac systems for further analysis.

Q: When is automatic humidity control utilized during PCR runs?

A: Automatic humidity control is active throughout the run, preserving sample integrity by preventing evaporation and condensation episodes. This is particularly beneficial during lengthy or high-temperature protocols.

Q: Where can the PCR-TC96 thermal cycler be most effectively used?

A: This model is suitable for molecular biology laboratories engaged in gene amplification, diagnostic research, and educational settings. Its compact design and robust build (ABS plastic, stainless steel) mean it fits well on benchtops and withstands everyday lab use.

Q: What processes does the gradient function support, and how does it benefit users?

A: Gradient functionality allows users to test multiple annealing temperatures simultaneously across the 96-well block. This streamlines protocol optimization, saving time and increasing the likelihood of achieving ideal amplification conditions for diverse DNA templates.

Q: How does the safety system protect both the operator and the samples?

A: The thermal cycler integrates over-temperature protection, which automatically halts operation if unsafe conditions arise. Additionally, a password lock prevents unauthorized access, safeguarding both the instrument and sensitive experimental data.

Q: What is the recommended sample volume range for optimal PCR results on this device?

A: The PCR-TC96 is optimized for sample volumes between 10 and 100 l per well, ensuring flexibility for varied molecular biology applications and supporting up to 96 reactions simultaneously in standard 0.2 ml tubes.

Tell us about your requirement
product

Price:  

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Scientific Instruments Category

Precision Digital Melting Point System

Precision Digital Melting Point System

Type : Digital Melting Point System

Automation Grade : Semiautomatic

Feature : Accurate temperature control, Digital readout, Programmable heating rate, Inbuilt fan

Core Components : PID Microprocessor controller, Capillary holder

Dimension (L*W*H) : 200 x 175 x 150 mm

Usage : Laboratory melting point determination

All Quartz Double Distillation

All Quartz Double Distillation

Type : All Quartz Double Distillation Unit

Automation Grade : Semiautomatic

Feature : Automatic shutoff, High chemical resistance, Low water feed cutoff

Core Components : Quartz Boiler, Quartz Condenser, Heater, Interlocking System

Dimension (L*W*H) : 450 × 250 × 600 mm

Usage : Laboratory/Research/Pharmaceutical Applications

Barometer

Barometer

Type : Aneroid Barometer

Automation Grade : Manual

Feature : Wall mountable, portable

Core Components : Sensitive aneroid capsule, gear mechanism

Dimension (L*W*H) : 100mm x 30mm x 100mm

Usage : Weather and atmospheric pressure measurement

Nessler Cylinder

Nessler Cylinder

Type : Nessler Cylinder, Flat Bottom / Round Bottom

Automation Grade : Manual

Feature : Clear Graduation, High Chemical Resistance, Leakproof

Core Components : Glass Cylinder with Graduations

Dimension (L*W*H) : Varies by capacity (e.g. 21 x 150 mm for 100 ml)

Usage : Colorimetric Analysis, Laboratory Chemical Testing