Back to top
Single Beam Spectrophotometer
Single Beam Spectrophotometer

Single Beam Spectrophotometer

Single Beam Spectrophotometer Specification

  • Power Source
  • 220V AC mains
  • Accuracy
  • 0.5% T
  • Temperature Range
  • Not applicable (Ambient operation)
  • Voltage
  • 220 V
  • Automation Grade
  • Semi-automatic
  • Frequency
  • 50/60 Hz
  • Measurement Range
  • 340 to 1000 nm
  • Model No
  • SB-11
  • Capacity
  • 1 cuvette at a time
  • Feature
  • User-friendly operations, accurate optics, stable photometric system
  • Core Components
  • Monochromator, Detector, Light Source, Sample Holder
  • Equipment Materials
  • High-grade ABS plastic and aluminum alloy
  • Type
  • Single Beam Spectrophotometer
  • Usage
  • Laboratory use for quantitative and qualitative analysis
  • Display Type
  • LCD digital display
  • Dimension (L*W*H)
  • 420 x 280 x 180 mm
  • Weight
  • Approx. 6 kg
  • Path Length
  • 10 mm
  • Detector Type
  • Silicon Photodiode
  • Interface
  • None/Optional RS232 port
  • Wavelength Accuracy
  • 2 nm
  • Photometric Range
  • 0200% T, -0.3 to 3 A
  • Operating Humidity
  • 85% RH, non-condensing
  • Calibration
  • Auto zero and blank
  • Data Output
  • Display only, no direct data output for standard model
  • Response Time
  • 3 seconds
  • Spectral Bandwidth
  • 4 nm
  • Lamp Life
  • Approx. 1000 hours
  • Sample Holder Type
  • 10 mm square cuvette holder
  • Light Source
  • Tungsten Halogen Lamp
  • Wavelength Repeatability
  • 1 nm
 
 

About Single Beam Spectrophotometer

Single Beam Spectrophotometer offered features single beam grating 1200 linesmm based optical system and working wavelength range from 2001000nm Also coming with band width support of 1 nm these systems can deliver wavelength accuracy of 05 nm wavelength repeatability of 01nm provision of automatically setting of wavelength and photometric accuracy of 01 T Some of the other features of the system includes photometric display range of 0330A0200T 09999C USB based data output port parallel printer port and Deuterium Lamp Tungsten Halogen Lamp options among others

Technical Specifications

Optical System

Single Beam Grating 1200 linesmm

Wavelength Range

2001000nm

Band Width

1 nm

Wavelength Accuracy

05 nm

Wavelength Repeatability

01nm

Wavelength Setting

Automatic

Photometric Accuracy

01 T

Photometric Repeatability

03 T

Photometric Display Range

0330A0200T 09999C

Stability

0002Ah 500nm

Stray Light

03T 220nm 360nm

Data Output Port

USB

Printer Port

Parallel Port

Display

12864 Dots LCD

Lamps

Deuterium Lamp Tungsten Halogen Lamp

Detector

Silicon Photodiode

Power Requirement

AC220V50 Hz



Reliable Performance for Laboratory Applications

The SB-11 spectrophotometer is tailored for academic research, pharmaceuticals, and chemical analysis, offering stable optics and dependable measurement accuracy. Its automatic zeroing and blank calibration streamline workflows, while the precise monochromator and silicon photodiode detector enable reproducible results for routine and advanced testing alike.


User-Friendly Design and Intuitive Operation

Enjoy straightforward operation with the digital LCD display and easy controls. The spectrophotometer features a single-cuvette holder, minimizing handling errors, and supports rapid measurement with a response time of 3 seconds. Its semi-automatic function and robust materials promote long-term and trouble-free laboratory use.


Durability and Enhanced Convenience

Constructed from high-grade ABS plastic and aluminum alloy, the SB-11 is built to withstand frequent laboratory handling. Auto calibration ensures ongoing accuracy, while the tungsten halogen light source offers a lamp life of approximately 1000 hours, minimizing maintenance and downtime. Optional RS232 interface expands data flexibility for laboratory needs.

FAQs of Single Beam Spectrophotometer:


Q: How does the SB-11 Single Beam Spectrophotometer achieve high measurement accuracy?

A: The SB-11 uses a tungsten halogen lamp and a precisely tuned monochromator, alongside a silicon photodiode detector. With wavelength accuracy of 2 nm and photometric accuracy of 0.5% T, the system consistently delivers reliable and reproducible results for quantitative and qualitative analysis.

Q: What is the process for calibrating the spectrophotometer before use?

A: Calibration is straightforward due to the auto zero and blank features. Prior to measurements, users simply insert a blank sample and follow on-screen instructions. The spectrophotometer automatically adjusts for background absorbance, ensuring accurate subsequent readings.

Q: When should the tungsten halogen lamp be replaced?

A: The lamp has a typical life of around 1000 hours under standard laboratory conditions. It should be replaced once its intensity diminishes or after reaching its rated operating hours to maintain consistent measurement quality.

Q: Where can the spectrophotometer be used effectively?

A: Designed for laboratory environments, the SB-11 is ideal for educational institutions, pharmaceutical labs, chemical analysis setups, and research facilities, operating in ambient conditions with humidity up to 85% RH (non-condensing).

Q: What types of samples can be measured with this device?

A: The SB-11 is suitable for liquid samples that can be held in 10 mm square cuvettes. Its measurement range spans 340 to 1000 nm, making it effective for various solutions in chemistry, biology, and pharmaceutical applications.

Q: How is data managed or exported from the SB-11 spectrophotometer?

A: By default, results are displayed clearly on the LCD digital display. For enhanced data management, an optional RS232 port is available for connection to external devices, though the standard model does not feature direct data output capabilities.

Q: What are the benefits of choosing this spectrophotometer for laboratory work?

A: The SB-11 offers rapid response time, stable photometric readings, and easy operation, ensuring minimal user error. Its robust design reduces maintenance, and the user-friendly features support efficient workflows, making it a practical and accurate choice for regular laboratory analysis.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Double Beam UV-VIS Spectrophotometer Category

Touch Screen Double Beam UV-Visible Spectrophotometer

Touch Screen Double Beam UV-Visible Spectrophotometer

Power Source : AC Mains Electric

Accuracy : Photometric accuracy: 0.3%T

Temperature Range : Room Temperature

Equipment Materials : Powder coated steel with chemicalresistant plastic housing

Usage : Quantitative and qualitative chemical analysis, absorption and transmittance measurements

Voltage : 220 V AC 10%

UV- Visible Software Spectrophotometer

UV- Visible Software Spectrophotometer

Power Source : Electric powered

Accuracy : 0.5% T

Temperature Range : Ambient to 45C

Equipment Materials : Corrosionresistant alloy frame, optical grade glass

Usage : Analytical lab, research, education

Voltage : 220 V

Microprocessor UV / VIS Spectrophotometer (Double Beam)

Microprocessor UV / VIS Spectrophotometer (Double Beam)

Power Source : AC mains

Accuracy : 0.5 nm (wavelength), 0.3% T (photometric)

Temperature Range : Ambient (10C40C)

Equipment Materials : ABS structure, highquality optical glass, and metal components

Usage : Laboratory analysis, Photometric measurements

Voltage : 220 V

Double Beam UV Visible Spectrophotometer

Double Beam UV Visible Spectrophotometer

Power Source : AC Mains

Accuracy : 0.5 nm wavelength accuracy

Temperature Range : Ambient, 5C to 45C operating

Equipment Materials : Highgrade ABS plastic body, Quartz optics

Usage : Quantitative and qualitative spectrophotometric analysis

Voltage : 220V AC