Single Beam Spectrophotometer Specification

  • Temperature Range
  • Not applicable (Ambient operation)
  • Accuracy
  • 0.5% T
  • Voltage
  • 220 V
  • Capacity
  • 1 cuvette at a time
  • Automation Grade
  • Semi-automatic
  • Measurement Range
  • 340 to 1000 nm
  • Core Components
  • Monochromator, Detector, Light Source, Sample Holder
  • Model No
  • SB-11
  • Frequency
  • 50/60 Hz
  • Feature
  • User-friendly operations, accurate optics, stable photometric system
  • Power Source
  • 220V AC mains
  • Equipment Materials
  • High-grade ABS plastic and aluminum alloy
  • Type
  • Single Beam Spectrophotometer
  • Usage
  • Laboratory use for quantitative and qualitative analysis
  • Display Type
  • LCD digital display
  • Dimension (L*W*H)
  • 420 x 280 x 180 mm
  • Weight
  • Approx. 6 kg
  • Operating Humidity
  • 85% RH, non-condensing
  • Interface
  • None/Optional RS232 port
  • Detector Type
  • Silicon Photodiode
  • Data Output
  • Display only, no direct data output for standard model
  • Photometric Range
  • 0-200% T, -0.3 to 3 A
  • Lamp Life
  • Approx. 1000 hours
  • Spectral Bandwidth
  • 4 nm
  • Response Time
  • 3 seconds
  • Sample Holder Type
  • 10 mm square cuvette holder
  • Light Source
  • Tungsten Halogen Lamp
  • Path Length
  • 10 mm
  • Wavelength Accuracy
  • 2 nm
  • Calibration
  • Auto zero and blank
  • Wavelength Repeatability
  • 1 nm
 
 

About Single Beam Spectrophotometer

Single Beam Spectrophotometer offered features single beam grating 1200 linesmm based optical system and working wavelength range from 2001000nm Also coming with band width support of 1 nm these systems can deliver wavelength accuracy of 05 nm wavelength repeatability of 01nm provision of automatically setting of wavelength and photometric accuracy of 01 T Some of the other features of the system includes photometric display range of 0330A0200T 09999C USB based data output port parallel printer port and Deuterium Lamp Tungsten Halogen Lamp options among others

Technical Specifications

Optical System

Single Beam Grating 1200 linesmm

Wavelength Range

2001000nm

Band Width

1 nm

Wavelength Accuracy

05 nm

Wavelength Repeatability

01nm

Wavelength Setting

Automatic

Photometric Accuracy

01 T

Photometric Repeatability

03 T

Photometric Display Range

0330A0200T 09999C

Stability

0002Ah 500nm

Stray Light

03T 220nm 360nm

Data Output Port

USB

Printer Port

Parallel Port

Display

12864 Dots LCD

Lamps

Deuterium Lamp Tungsten Halogen Lamp

Detector

Silicon Photodiode

Power Requirement

AC220V50 Hz



Reliable Performance for Laboratory Applications

The SB-11 spectrophotometer is tailored for academic research, pharmaceuticals, and chemical analysis, offering stable optics and dependable measurement accuracy. Its automatic zeroing and blank calibration streamline workflows, while the precise monochromator and silicon photodiode detector enable reproducible results for routine and advanced testing alike.


User-Friendly Design and Intuitive Operation

Enjoy straightforward operation with the digital LCD display and easy controls. The spectrophotometer features a single-cuvette holder, minimizing handling errors, and supports rapid measurement with a response time of 3 seconds. Its semi-automatic function and robust materials promote long-term and trouble-free laboratory use.


Durability and Enhanced Convenience

Constructed from high-grade ABS plastic and aluminum alloy, the SB-11 is built to withstand frequent laboratory handling. Auto calibration ensures ongoing accuracy, while the tungsten halogen light source offers a lamp life of approximately 1000 hours, minimizing maintenance and downtime. Optional RS232 interface expands data flexibility for laboratory needs.

FAQs of Single Beam Spectrophotometer:


Q: How does the SB-11 Single Beam Spectrophotometer achieve high measurement accuracy?

A: The SB-11 uses a tungsten halogen lamp and a precisely tuned monochromator, alongside a silicon photodiode detector. With wavelength accuracy of 2 nm and photometric accuracy of 0.5% T, the system consistently delivers reliable and reproducible results for quantitative and qualitative analysis.

Q: What is the process for calibrating the spectrophotometer before use?

A: Calibration is straightforward due to the auto zero and blank features. Prior to measurements, users simply insert a blank sample and follow on-screen instructions. The spectrophotometer automatically adjusts for background absorbance, ensuring accurate subsequent readings.

Q: When should the tungsten halogen lamp be replaced?

A: The lamp has a typical life of around 1000 hours under standard laboratory conditions. It should be replaced once its intensity diminishes or after reaching its rated operating hours to maintain consistent measurement quality.

Q: Where can the spectrophotometer be used effectively?

A: Designed for laboratory environments, the SB-11 is ideal for educational institutions, pharmaceutical labs, chemical analysis setups, and research facilities, operating in ambient conditions with humidity up to 85% RH (non-condensing).

Q: What types of samples can be measured with this device?

A: The SB-11 is suitable for liquid samples that can be held in 10 mm square cuvettes. Its measurement range spans 340 to 1000 nm, making it effective for various solutions in chemistry, biology, and pharmaceutical applications.

Q: How is data managed or exported from the SB-11 spectrophotometer?

A: By default, results are displayed clearly on the LCD digital display. For enhanced data management, an optional RS232 port is available for connection to external devices, though the standard model does not feature direct data output capabilities.

Q: What are the benefits of choosing this spectrophotometer for laboratory work?

A: The SB-11 offers rapid response time, stable photometric readings, and easy operation, ensuring minimal user error. Its robust design reduces maintenance, and the user-friendly features support efficient workflows, making it a practical and accurate choice for regular laboratory analysis.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Double Beam UV-VIS Spectrophotometer Category

Spectrophotometer/ Pharmacy Lab Equipments

Spectrophotometer/ Pharmacy Lab Equipments

Display Type : Digital LCD display

Temperature Range : Ambient (typically 5C to 40C)

Measurement Range : 190 1100 nm

Type : UVVisible Spectrophotometer

Automation Grade : Semiautomatic

Weight : Approx. 1020 kg

Single Beam UV Visible Spectrophotometer

Single Beam UV Visible Spectrophotometer

Display Type : LCD Digital Display

Temperature Range : Room Temperature Operation

Measurement Range : 190 nm 1000 nm

Type : Single Beam UVVisible Spectrophotometer

Automation Grade : SemiAutomatic

Weight : Approx. 8 kg

Double Beam Spectrophotometer

Double Beam Spectrophotometer

Display Type : Large LCD Display

Temperature Range : Ambient to 45C

Measurement Range : 1901100 nm

Type : Double Beam Spectrophotometer

Automation Grade : SemiAutomatic

Weight : Approx. 15 kg

UV- Visible Software Spectrophotometer

UV- Visible Software Spectrophotometer

Display Type : Digital LCD display with software interface

Temperature Range : Ambient to 45C

Measurement Range : 190 nm to 1100 nm

Type : UVVisible Software Spectrophotometer

Automation Grade : Semiautomatic

Weight : Approximately 15 kg