Biosafety Cabinet Specification

  • Frequency
  • 50 Hz
  • Accuracy
  • 99.99% HEPA Filtration Efficiency
  • Measurement Range
  • 0.3 microns @ 99.99% efficiency
  • Power Source
  • Electric
  • Temperature Range
  • Ambient to 50C
  • Automation Grade
  • Semi-Automatic
  • Capacity
  • 1200 mm working area
  • Voltage
  • 220-240 V AC
  • Model No
  • BSC-1200A2
  • Core Components
  • HEPA Filter, UV Lamp, Blower, Control Panel, Fluorescent Light
  • Feature
  • High-efficiency Particulate Air Filtration, UV Germicidal Protection, Ergonomic Design, Low Noise Operation
  • Equipment Materials
  • Stainless Steel (Inner), Powder Coated Mild Steel (Outer)
  • Type
  • Class II, Type A2
  • Usage
  • Laboratory Biological Safety and Containment
  • Display Type
  • Digital Display
  • Dimension (L*W*H)
  • 1200 x 750 x 1900 mm
  • Weight
  • Approx. 180 kg
  • Noise Level
  • Less than 65 dB
  • Exhaust System
  • Ductless
  • Cabinet Lighting
  • Fluorescent and UV
  • Work Surface Height
  • 750 mm
  • Electrical Safety
  • MCCB Protection
  • Front Sash
  • Tempered Safety Glass, Vertical Sliding
  • Operation Mode
  • Continuous Duty
  • HEPA Filter Efficiency
  • 99.99% for particles of 0.3 microns
  • Illumination
  • 800 Lux (Fluorescent Lighting)
  • Air Flow Velocity
  • 0.35-0.55 m/s
  • Pressure Gauge
  • In-built (for filter monitoring)
  • UV Lamp
  • 15W - Germicidal
 
 

About Biosafety Cabinet

 Biosafety Cabinet

    Working Size    Size of HEPA Filter      No. of HEPA Filter       Illumination

A     2' x 2'x 2'              2' x 2' x 6"                       1                              1 x 20 W

B     3' x 2'x 2'              3' x 2' x 6"                       1                              1 x 20 W

C     4' x 2'x 2'              4' x 2' x 6"                       2                              1 x 30 W

D     6' x 2'x 2'              3' x 2' x 6"                       1                              1 x 30 W

OPTIONAL :-

(i) Virus burn out unit

2' x 2' x 2'

3' x 2' x 2'

4' x 2' x 2'

6' x 2' x 2' 



Superior Filtration and Safety

Equipped with a high-efficiency HEPA filter, the BSC-1200A2 removes 99.99% of airborne contaminants at 0.3 microns, ensuring a clean and safe working environment. The vertical sliding tempered safety glass sash and ergonomic design further enhance operator and sample protection.


Advanced Illumination and Controls

The cabinet features dual lighting modes: powerful 800 lux fluorescent illumination for clear visibility and a 15W UV germicidal lamp for enhanced decontamination. The integrated digital display and semi-automatic control panel simplify operation and filter status monitoring.


Quiet and Comfortable Operation

Operating at noise levels below 65 dB and with a low-vibration blower, this biosafety cabinet ensures a comfortable workspace, even during extended use. The spacious 1200 mm working area makes it suitable for various laboratory tasks and workflows.

FAQ's of Biosafety Cabinet:


Q: How does the HEPA filter in the BSC-1200A2 biosafety cabinet ensure laboratory safety?

A: The HEPA filter captures 99.99% of particles as small as 0.3 microns, effectively removing harmful biological contaminants from the air to keep both samples and personnel safe during laboratory processes.

Q: What is the purpose of the cabinet's ductless exhaust system?

A: The ductless exhaust system recirculates filtered air back into the laboratory after removing contaminants, which eliminates the need for external ducts and facilitates flexible installation in various laboratory layouts.

Q: When should the UV germicidal lamp be used in the biosafety cabinet?

A: The 15W UV germicidal lamp should be operated before and after experimental procedures to sterilize the interior surfaces of the cabinet and reduce the risk of cross-contamination.

Q: Where can the BSC-1200A2 biosafety cabinet be used effectively?

A: This cabinet is ideal for use in research laboratories, pharmaceutical manufacturing, clinical diagnostic centers, and educational institutions that require stringent biological containment and safety.

Q: What benefits does the in-built pressure gauge provide?

A: The in-built pressure gauge enables real-time monitoring of filter condition, alerting users to any changes in air flow that could indicate filter saturation, thereby ensuring consistent filtration performance.

Q: How is user comfort addressed during cabinet operation?

A: With a low noise level (under 65 dB), ergonomic work surface height (750 mm), and ample illumination, the cabinet supports extended laboratory work while minimizing operator fatigue.

Q: What are the main materials used in the BSC-1200A2 cabinet construction?

A: The inner chamber is constructed from stainless steel for superior corrosion resistance and easy cleaning, while the outer surface is powder-coated mild steel for added durability and aesthetics.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Laboratories Instruments Equipment Category

Glass Beakers

Glass Beakers

Usage : Laboratory, Educational, Research

Type : Low Form / Tall Form Beaker

Core Components : Beaker Body, Pouring Spout

Weight : Varies by capacity, ~80g (100ml) to 480g (1000ml)

Equipment Materials : Borosilicate Glass

Capacity : 100ml, 250ml, 500ml, 1000ml (varies per option)

Serological Water Bath

Serological Water Bath

Usage : Laboratory, Clinical, Biochemical Applications

Type : Serological Water Bath

Core Components : Heater, Thermostat, Control Panel, Water Chamber

Weight : Approx. 1428 kg (depending on model/capacity)

Equipment Materials : Double walled, Inner chamber made of stainless steel (SS 304), outer chamber made of mild steel powder coated or stainless steel

Capacity : 12 Ltrs, 18 Ltrs, 25 Ltrs, 35 Ltrs, 45 Ltrs, 55 Ltrs (as per requirement)

Vertical Autoclave Double Drum

Vertical Autoclave Double Drum

Usage : Sterilization of medical instruments, laboratory use

Type : Vertical Autoclave, Double Drum

Core Components : Chambers, Pressure gauge, Heater, Controller, Lid lock system

Weight : Approx 65 kg

Equipment Materials : Stainless Steel (SS304/316)

Capacity : 2 x 22 liters (Double Drum)

Orbital Shaking Incubator

Orbital Shaking Incubator

Usage : Laboratory, Research, Cell Culture

Type : Orbital Shaking Incubator

Core Components : Motor, Heater, Controller

Weight : Approx. 80 kg

Equipment Materials : Powder Coated Steel & Stainless Steel (Inner Chamber)

Capacity : 250 L