Water Distillation Apprutus
Water Distillation Apprutus

Water Distillation Apprutus

Water Distillation Apprutus Specification

  • Humidity
  • Ambient
  • Temperature
  • Operating up to 100C
  • Automation Grade
  • Semi-Automatic
  • Max Height
  • 600 mm
  • Features
  • Quartz Heater, Pyrogen Free Distillate, Rust Proof Construction, Energy Efficient
  • Mounting Type
  • Table Top
  • Frequency
  • 50 Hz
  • Operating Voltage
  • 220V
  • Application
  • Laboratory, Medical, Pharmacy, Research
  • Power Supply
  • 220V AC, 50Hz
  • Port Size
  • Inlet: 1/2 inch, Outlet: 1/2 inch
  • Usage
  • Distillation of Water
  • Capacity
  • 4 L/hr
  • Machine Weight
  • 8 kg (approx.)
  • Control Mode
  • Manual
  • Safety Features
  • Overheating Protection, Water Level Sensor
  • Equipment Type
  • Water Distillation Apparatus
  • Condenser Type
  • Coiled Glass Condenser
  • Color
  • Transparent with Metallic Parts
  • Installation
  • Easy Bench Mounting
  • Cooling Water Requirement
  • 1 L/min
  • Body Material
  • Borosilicate Glass and Stainless Steel
  • Heater Type
  • Quartz Heater
  • Distillate Quality
  • Conductivity < 1.0 S/cm, pH 5.5 to 7.0
 
 

About Water Distillation Apprutus

Distillation Apparatus KFW.Automatic electrically heated all glass apparatus, N.P.L. Design, Heater embedded in spiral glass tube complete with metal stand, M.S. Rod, clamps, etc.

Flask Cap KFW

KFW Single Distillation without cut off

 

3 Litre

Single Distillation without cut off

3 Litre

Double Distillation without cut off

3 Litre

Triple Distillation without cut off

5 Litre

Single Distillation without cut off

5 Litre

Double Distillation without cut off

5 Litre

Triple Distillation without cut off

10 Litre

Single Distillation without cut off

10 Litre

Double Distillation without cut off

10 Litre

Triple Distillation without cut off

 



Advanced Distillate Purity

Achieve distillate with ultra-low conductivity (<1.0 S/cm) and a neutral pH (5.57.0), ensuring suitability for sensitive analytical procedures and critical laboratory applications. Pyrogen-free water production supports advanced research, medical, and pharmaceutical requirements, minimizing risks of contamination.


Safety-First Design

The system incorporates vital safety features such as overheating protection and a water level sensor, safeguarding both user and equipment. Its robust, rust-proof construction utilizing borosilicate glass and stainless steel enhances longevity and reliability in demanding environments.


Effortless Installation and Operation

Engineered for easy bench or table top mounting and straightforward manual controls, this apparatus can be set up swiftly in any lab. Consistent output and user-friendly maintenance make it an excellent choice for laboratories seeking efficiency and convenience.

FAQs of Water Distillation Apprutus :


Q: How does the borosilicate glass and stainless steel construction benefit the distillation process?

A: Borosilicate glass offers excellent chemical resistance and thermal stability, while stainless steel provides strength and corrosion resistance. This combination ensures long-lasting, rust-proof performance, maintaining water purity and equipment longevity.

Q: What kind of water quality can I expect from this distillation apparatus?

A: The apparatus produces high-purity water with conductivity below 1.0 S/cm and a pH between 5.5 and 7.0, suitable for laboratory, medical, and research purposes. The distillate is also pyrogen-free.

Q: When should this apparatus be used for water distillation?

A: This apparatus is ideal whenever ultra-pure, contaminant-free water is required, especially in laboratory, pharmaceutical, medical, or research settings where reliable distilled water is essential.

Q: Where can the water distillation apparatus be installed?

A: Its compact, bench-mountable design allows for easy installation on lab tables or benches, making it suitable for laboratories, research facilities, pharmacies, and similar environments.

Q: What is the typical process for using this distillation apparatus?

A: Simply fill the water tank, secure the connections, and start the apparatus using manual controls. The system will distill up to 4 liters per hour, with distilled water collected automatically, while safety features monitor temperature and water levels.

Q: How do the safety features enhance usage?

A: Overheating protection and the water level sensor help prevent accidents, safeguard the heater, and alert users if the apparatus is at risk, making operation more secure and reliable.

Q: What are the main benefits of using this apparatus?

A: Users benefit from high water purity, energy efficiency, and rust-proof, durable construction. The straightforward manual operation and easy mounting make it practical for regular laboratory use.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Laboratory Glassware Category

Pipettes

Pipettes

Control Mode : Manual, Thumboperated or Electronic (depending on model)

Resolution : 0.1 L

Application : Used for liquid transfer, measurement, analytical, and biological laboratory applications

Power Supply : Not required for manual pipettes; Electronic models use 2x AAA batteries or rechargeable battery

Mounting Type : Handheld

Equipment Type : Micropipette / Laboratory Pipette

Student Organ Bath (Double Unit)

Student Organ Bath (Double Unit)

Control Mode : Manual control using lever or knob

Resolution : As per measurement apparatus used

Application : Physiology and pharmacology experiments, isolated tissue/organ studies

Power Supply : 220V AC, 50 Hz

Mounting Type : Benchtop

Equipment Type : Student Organ Bath Double Unit

Digital Photo Colorimeter Micro Controller

Digital Photo Colorimeter Micro Controller

Control Mode : Micro controller based

Resolution : 0.01 OD

Power Supply : 220V AC 10% 50Hz

Equipment Type : Digital Photo Colorimeter (Micro Controller)

Digital Colony Counter

Digital Colony Counter

Control Mode : Digital

Resolution : 1 colony

Application : Microbiological Colony Counting

Power Supply : 230 V AC, 50 Hz

Mounting Type : Table top

Equipment Type : Digital Colony Counter