Floculator four Jar Test Apparatus Health care,Lif Specification

  • Interface Type
  • Manual control panel
  • Humidity
  • Up to 80% (non-condensing)
  • Operating Voltage
  • 230 V AC
  • Features
  • Stainless steel stirring rods, uniform illumination, compact design
  • Frequency
  • 50 Hz
  • Automation Grade
  • Manual
  • Temperature
  • Ambient
  • Test Range
  • Suitable for standard jar test (flocculation/sedimentation studies)
  • Measuring Range
  • 20-120 RPM
  • Equipment Type
  • Four Jar Flocculator (Jar Test Apparatus)
  • Number of Specimens
  • 4 beakers (jars)
  • Mounting Type
  • Tabletop
  • Accuracy
  • 2 RPM
  • Power Supply
  • 230V AC, 50 Hz
  • Response Time
  • Immediate
  • Max Height
  • Approx. 50 cm
  • Specimen Size
  • 1 litre per jar
  • Display Type
  • Digital LED display
  • Application
  • Water and wastewater treatment lab, flocculation and coagulation studies
  • Resolution
  • 1 RPM
  • Usage
  • Laboratory analytical testing
  • Capacity
  • 4 x 1 litre jars
  • Machine Weight
  • Approx. 13-15 kg
  • Test Speed
  • 20-120 RPM (variable)
  • Test Width
  • 4 beaker layout
  • Control Mode
  • Digital RPM controller with timer
 
 

About Floculator four Jar Test Apparatus Health care,Lif

Floculator four Jar Test Apparatus Health care,Life Science Lab Equipment Analytical KFW : 

Features 

  • Specially designed for use in water treatment plant as jar test apparatus

  • Provides identical test conditions for all samples

  • Stirring shaft can be removed without disturbing other stirrers

  • Illuminator base made of acrylic sheet provides diffused cold light through floc. Samples


Specifications:-

  • Speed: variable from 5 to 150 rpm's with accuracy of +/- 1 rpm

  • Display: digital 12 mm red led display for rpm

  • Jar: for 1000 ml x 6 nos

  • Paddles: stirring paddles made of s. S. - 6 nos

  • Illumination: fluorescent lamps



Advanced Design for Accurate Flocculation Studies

The apparatus utilizes stainless steel stirring rods and uniform diffused illumination, facilitating consistent mixing and visibility for sedimentation and flocculation experiments. Adjustable speed and programmable timer allow precise control over test conditions, while the stable non-slip base ensures operator safety.


Versatile and User-Friendly Operation

The Floculator is easily operated via a manual control panel, permitting stepless speed adjustments from 20 to 120 RPM, and quick setup. Its removable beaker support enables straightforward cleaning and handling, catering to daily use in busy laboratory environments.


Durability and Safety Prioritized

A robust powder-coated steel chassis protects against corrosion, and overload protection mechanisms defend sensitive components, ensuring long-term reliability. The non-slip base maintains instrument stability, crucial for safe laboratory operation.

FAQs of Floculator four Jar Test Apparatus Health care,Lif:


Q: How does the Floculator Four Jar Test Apparatus operate for water treatment analysis?

A: This apparatus facilitates flocculation and sedimentation studies by using four independently stirred jars, enabling precise control of mixing and settling conditions. Users set mixing speed (20120 RPM) and timer using the manual control panel, observing reactions under uniform illumination.

Q: What is the benefit of programmable digital timer and variable speed control in jar testing?

A: The programmable timer (up to 99 minutes) and stepless speed control allow researchers to simulate various test scenarios, ensuring reproducibility and accuracy in flocculation tests for optimized chemical dosing and treatment protocols.

Q: When should laboratories use this equipment during water or wastewater analysis?

A: It is typically employed during initial process development or quality control stages to evaluate appropriate coagulant/flocculant dosages and settling times, assisting in scaling up precise water treatment protocols.

Q: Where can this Four Jar Floculator be installed?

A: Designed for laboratory settings, it is best mounted on firm tabletops in water research facilities, municipal treatment plants, environmental labs, and similar analytical spaces in compliance with ambient conditions (5C40C, RH <80%).

Q: What is the cleaning process for the beaker supports and paddles?

A: The beaker supports are removable, simplifying cleaning and maintenance. Stainless steel paddles and borosilicate glass beakers should be gently washed and dried after each use to maintain hygienic and optimal operating conditions.

Q: How does diffused base illumination enhance jar test procedures?

A: Diffused illumination provides uniform light for all jars, improving visibility of flocculation progress and sedimentation. This aids accurate observation and reliable decision-making during analytical studies.

Q: What safety features are included to ensure safe operation?

A: The apparatus offers overload protection to prevent electrical issues, a stable non-slip base to reduce accident risk, and a powder-coated body for enhanced durability in aggressive laboratory environments.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Testing & Measuring Equipment Category

Humidity Cabinet Complete With Fully Digital Contr

Humidity Cabinet Complete With Fully Digital Contr

Features : Microprocessor control, Alarm system, Digital calibration

Automation Grade : Fully Automatic

Capacity : 60 liters

Application : Laboratory humidity control, material testing

Usage : Humidity and temperature testing

Mounting Type : Benchtop / Floor

Tincture Press Healthcare,Lab & Life Science Lab Equipment Tincture Press - KFW

Tincture Press Healthcare,Lab & Life Science Lab Equipment Tincture Press - KFW

Features : Heavy Duty, Corrosion Resistant, Easy Cleaning, Userfriendly

Automation Grade : Manual

Capacity : 500 ml (Press Volume)

Application : Healthcare, Laboratory, Pharmaceuticals

Usage : Tincture Extraction, Herbal Extracts, Lab Sample Preparation

Mounting Type : Table Top

Monsanto Type Tablet Hardness Tester

Monsanto Type Tablet Hardness Tester

Features : Portable, easy to operate, durable body, precise analog reading

Automation Grade : Manual

Capacity : 20 kgf

Application : Used to test the hardness of tablets in pharmaceutical laboratories

Usage : Laboratory testing of tablet hardness

Mounting Type : Bench top, handheld

Volumetric Burette

Volumetric Burette

Features : Clear Calibrations, PTFE Stopcock, Durable Glass Construction, Chemical Resistant

Automation Grade : Manual

Capacity : 50 ml / 100 ml

Application : Laboratory Liquid Measurement, Titration

Usage : Quantitative Chemical Analysis

Mounting Type : Clamp Stand Mountable