Back to top
Heating Mantle
Heating Mantle

Heating Mantle

Heating Mantle Specification

  • Accuracy
  • 2C
  • Feature
  • Uniform Heating, Energy Efficient, Corrosion Resistance
  • Power Source
  • Electric
  • Model No
  • HM-500
  • Temperature Range
  • Up to 350C
  • Frequency
  • 50 Hz
  • Automation Grade
  • Manual
  • Core Components
  • Heating Element, Body, Temperature Control Knob, Power Cord
  • Capacity
  • 500 ml
  • Voltage
  • 230 V AC
  • Measurement Range
  • Suitable for flasks up to 500 ml
  • Equipment Materials
  • Mild Steel Outer Body with Powder Coating, Fiber Glass Netting
  • Type
  • Laboratory Heating Mantle
  • Usage
  • Boiling and heating laboratory liquids
  • Display Type
  • Analog
  • Dimension (L*W*H)
  • Approx 24 x 24 x 18 cm
  • Weight
  • Approx 1.5-2.5 kg (depends on capacity)
  • Plug Type
  • 3 Pin Plug, ISI Marked
  • Maximum Flask Compatibility
  • Round Bottom Flask up to 500 ml
  • Color
  • Blue & White
  • Operating Environment
  • Indoor Laboratory Use
  • Cord Length
  • 1.5 meters
  • Heating Element Material
  • Nichrome Wire
  • Safety Features
  • Shock Proof Design, Overheat Protection
  • Insulation
  • High grade glass wool for thermal efficiency
  • Temperature Control
  • Stepless variable control
  • Surface Finish
  • Powder Coated, Rust Proof
 
 

About Heating Mantle

We offer a unique range ofHeating Mantle to our clients. These are developed under the guidance of our experts and in accordance with industry defined parameters. These are manufactured by using aluminum sheet and are logged with special glass wool. These mantles are made to accommodate several sizes of round bottle flask. Mantles are powder coated with a textured Siemens gray finish. Our mantles have an enclosed heating system, which is designed to avoid these dangers.

 

Capacity

Watt-ages

50ml

60

100ml

60

250ml

150

500ml

200

1 liters

300

2 liters

450

3 liters

450

5 liters

600

10 liters

2x500



 



Superior Thermal Efficiency

Featuring high-grade glass wool insulation and a fiber glass netting design, this heating mantle delivers exceptional heat retention and uniform distribution, resulting in efficient energy consumption and reliable performance during laboratory experiments. The powder-coated mild steel body enhances durability and corrosion resistance.


User-Friendly Temperature Control

Equipped with an analog, stepless variable control knob, the HM-500 allows precise adjustment of temperature up to 350C with an accuracy of 2C. Overheat and shock proof safety features further ensure secure and dependable laboratory operation for all users.


Engineered for Laboratory Safety

Designed for indoor laboratory use, this heating mantle fulfills essential safety standards with its ISI-marked certification, shock proof construction, overheat protection, and rust-resistant finish. The ergonomic blue and white exterior, combined with a 1.5-meter power cord and 3-pin plug, makes it convenient and compliant with typical lab setups.

FAQ's of Heating Mantle:


Q: How do I use the HM-500 Heating Mantle safely in a laboratory setting?

A: To operate the HM-500 safely, place the mantle on a stable surface, connect to a 230V AC supply with the provided 3-pin plug, and ensure the maximum flask size is 500 ml. Utilize the stepless temperature control knob to set the desired heat, and always monitor the analog display. The device includes shock proof and overheat protection features for added safety.

Q: What benefits does the glass wool insulation provide in this heating mantle?

A: High-grade glass wool insulation enhances thermal efficiency by minimizing heat loss, promoting uniform heating, and reducing energy consumption. This results in consistent temperature performance for precise laboratory applications.

Q: When should I use this heating mantle instead of a hot plate?

A: The HM-500 heating mantle is recommended over hot plates when heating or boiling liquids in round bottom flasks, as it provides gentle, even heating and avoids the risk of glassware stress or localized overheating common with flat hot plates.

Q: Where can this heating mantle be best utilized?

A: This heating mantle is specifically designed for controlled, indoor laboratory environments such as research institutions, academic laboratories, or industrial quality control labs. Its compact size and robust safety features make it ideal for bench-top operations.

Q: What is the process for controlling the temperature on this model?

A: To adjust the temperature, use the analog stepless variable control knob located on the mantle. The temperature can be precisely set up to 350C, with the analog indicator allowing real-time monitoring of your chosen heat level.

Q: What is the primary usage of the HM-500 laboratory heating mantle?

A: The HM-500 is used primarily for boiling and uniformly heating laboratory liquids in round bottom flasks, up to a 500 ml capacity. It is suitable for a variety of laboratory techniques requiring precise thermal control.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Laboratories Instruments Equipment Category

Digital Heating Mantle

Digital Heating Mantle

Price 1200 INR / Piece

Minimum Order Quantity : 1 Piece

Feature : Energy efficient, Uniform heating, Safety features

Usage : Laboratory chemical heating

Display Type : Digital Display

Accuracy : 2C

Glass Beakers

Glass Beakers

Price 45 INR / Piece

Minimum Order Quantity : 1 Piece

Feature : Chemically resistant, clear visibility, easy pouring

Usage : Laboratory, Educational, Research

Display Type : Graduated scale

Accuracy : Graduated 5% of full scale

Magnetic Stirrer

Magnetic Stirrer

Feature : Variable speed control, corrosionresistant top

Usage : Mixing and stirring chemical solutions in laboratories

Display Type : Analog/Scale Markings

Accuracy : 5 rpm

Autoclave Vertical

Autoclave Vertical

Feature : Double Safety Lock, Auto Pressure Release

Usage : Laboratory Sterilization

Display Type : Analog Pressure Gauge

Accuracy : 1C